Browse Articles
Discover research articles across all indexed journals
Accuracy of infusion flow rates and bolus doses for portable infusion pump
Abstract This study aimed to investigate the flow rate accuracy and bolus doses of four portable pumps with different mechanisms. We evaluated two electronic (COOPDECH Amy PCA [Amy] and CADD-Solis) and two elastomeric balloon-type pumps (COOPDECH Balloonjector and Rakurakufuser) under the following conditions: placement with an epidural catheter, operation on a shaking table, warming to 32 °C, and at room temperature (control, 25 °C). Amy maintained consistent flow rates across all conditions. The CADD-Solis also exhibited consistent flow rates, with minor yet statistically significant changes upon epidural catheter placement (− 5.0%, P = 0.005) and motion conditions (4.2%, P = 0.015). The Balloonjector and Rakurakufuser exhibited flow rate variations over time, and temperature increases significantly increased flow rates by 24.3% (P < 0.001) and 20.3% (P < 0.001), respectively. Bolus volume accuracy for the Amy, Balloonjector, and Rakurakufuser was not significantly affected under different conditions. The CADD-Solis showed a slight decrease in bolus volume with an epidural catheter (mean difference, 0.3 mL; P = 0.003). The electronic pumps maintained consistent flow rates across various conditions, whereas elastomeric balloon pumps exhibited variable rates influenced by time and temperature, increasing the risk of medication overdose. Bolus dosing accuracy was clinically satisfactory for all pump mechanisms.
Mechanical behavior and meso-degradation mechanism of cemented paste backfill under the coupled effect of disturbance damage and dry-wet cycles
A quantum crystallographic protocol for general use
Abstract Quantum crystallography has become ever more important in recent years for the accurate determination of molecular and crystal structures. The results of quantum crystallographic refinements of X-ray data are as accurate and precise as from neutron diffraction and they give access to the complete electronic structure of the compound under investigation. Is the method now mature enough and easy enough to use to extend and ultimately supersede standard X-ray crystal structure determination routines? We utilize the world’s most common crystal structure—the YLID test crystal that every owner of an X-ray diffractometer receives with their machine—to show under which circumstances routine, low-resolution, and even room-temperature measurements can be subjected to quantum crystallographic refinement. Based on this, we describe a quantum crystallographic protocol step by step that makes application of quantum crystallographic refinement easy to use and reproducible. We encourage that valuable YLID test measurements are not discarded but made available for method development, increasing the availability of repeated measurements from a handful to tens of thousands.
Heuristically enhanced multi-head attention based recurrent neural network for denial of wallet attacks detection on serverless computing environment
Molecular mapping of a novel locus S68 for intrasubspecific hybrid sterility in indica-indica hybrid
Advances in the recombinase polymerase amplification platform for urogenital schistosomiasis diagnosis (ShDraI-RPA) towards implementation at the point-of-care
Identification and validation of a novel machine learning model for predicting severe pelvic endometriosis: A retrospective study
SIRT1-based therapy targets a gene program involved in mitochondrial turnover in a model of retinal neurodegeneration
Serum neurofilament heavy chain predicts post-stroke cognitive impairment
The influence of ultrasonic shot peening on the microstructure and fatigue behavior of TC17 alloy
Abstract This research presents a quantitative analysis of TC17 alloy subjected to ultrasonic shot peening (USP) treatment. The effects of USP treatment under different Almen intensities on surface roughness, microstructure, plastic strain range, microhardness, residual stress, fatigue behavior and strain gradient of TC17 alloy were analyzed. Results show that increasing Almen intensity from 0.15 mmA to 0.25 mmA leads to a 27% increase in surface roughness, a 12% increase in surface compressive residual stress value, a 29% increase in the depth of compressive residual stress layer, and a 6.7% increase in the maximum value of compressive residual stress. Microstructural analysis reveals material stacking, pores, and microcracks on the specimen surface and grain refinement characteristics in the surface and subsurface layers. Strain gradient analysis shows that the deformation layer depth is uniformly distributed. An increase in Almen intensity leads to a higher degree of plastic deformation and work hardening, and the increase in compressive residual stress layer depth counteracts early fatigue failure caused by high roughness.
System expansion is needed to handle the multifunctionality of food items in environmental impact assessment
High antagonistic activity and antibiotic resistance of flavobacteria of polar microbial freshwater mats on King George Island in maritime Antarctica
Automated assessment of simulated laparoscopic surgical skill performance using deep learning
Abstract Artificial intelligence (AI) has the potential to improve healthcare and patient safety and is currently being adopted across various fields of medicine and healthcare. AI and in particular computer vision (CV) are well suited to the analysis of minimally invasive surgical simulation videos for training and performance improvement. CV techniques have rapidly improved in recent years from accurately recognizing objects, instruments, and gestures to phases of surgery and more recently to remembering past surgical steps. Lack of labeled data is a particular problem in surgery considering its complexity, as human annotation and manual assessment are both expensive in time and cost, and in most cases rely on direct intervention of clinical expertise. In this study, we introduce a newly collected simulated Laparoscopic Surgical Performance Dataset (LSPD) specifically designed to address these challenges. Unlike existing datasets that focus on instrument tracking or anatomical structure recognition, the LSPD is tailored for evaluating simulated laparoscopic surgical skill performance at various expertise levels. We provide detailed statistical analyses to identify and compare poorly performed and well-executed operations across different skill levels (novice, trainee, expert) for three specific skills: stack, bands, and tower . We employ a 3-dimensional convolutional neural network (3DCNN) with a weakly-supervised approach to classify the experience levels of surgeons. Our results show that the 3DCNN effectively distinguishes between novices, trainees, and experts, achieving an F1 score of 0.91 and an AUC of 0.92. This study highlights the value of the LSPD dataset and demonstrates the potential of leveraging 3DCNN-based and weakly-supervised approaches to automate the evaluation of surgical performance, reducing reliance on manual expert annotation and assessments. These advancements contribute to improving surgical training and performance analysis.
Awareness and perception of physicians about forgery and counterfeiting in the medical field in Egypt
Abstract Medical records may act as one of the legal pieces of evidence in the court. A complete and correct medical record contains a chronological health history of the patient, and it is one of the keys to resolving cases of alleged malpractice. The aim is to emphasize the importance of strict rules and training to ensure medical documents are handled properly and the prevalence of signature forgery in medical reports. This cross-sectional descriptive study was conducted with a sample of 300 randomly selected physicians from hospitals in Fayoum, Egypt, between 2024 and 2025. According to the opinions of 133 physicians (44.3%), forgery and counterfeiting are relatively common in the medical sector; 81 physicians (27%) believed it is common, and 9 physicians (3%) considered it very common, especially in medical reports. 186 (75.6%) were forged medical reports. 185 (61.7%) blamed it on inadequate supervision, while 162 (54%) said it was done to get money. This is followed by 160 doctors (53.3%) who cite respect for the senior and following his instructions if asked to signature in place. Importantly, the overwhelming support for enhanced oversight and education indicates a collective recognition of the necessity for systemic changes to combat forgery in the medical field.