Noise suppression and enhanced energy resolution in NiO/<i>β</i>-Ga2O3 radiation detectors

X X. Y. Pei (School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,) X X. D. Meng (Institute of Nuclear Energy Safety Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences 2 , Hefei 230088,) L L. Ren Y Y. C. Han (Institute of Nuclear Energy Safety Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences 2 , Hefei 230088,) N N. Sun W W. Z. Xu (School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,) F F.-F. Ren (School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,) D D. W. Yan (School of Integrated Circuits, Jiangnan University 2 , Wuxi 214122,) Y Y. Yang S S. L. Gu (School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,) R R. Zhang J J. D. Ye (School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,)

Abstract

In this Letter, we investigated the noise sources in NiO/β-Ga2O3 p–n heterojunctions and demonstrated the field management for noise suppression to enhance radiation detection performance. Combining TCAD simulations and experimental electrical analysis, we identified two primary noise sources, including shot noise originating from carrier density fluctuations and non-uniform carrier drift velocities, and flicker noise associated with localized carrier trapping centers. To mitigate these noise contributions, we developed a large-area (1 × 1 mm2) NiO/β-Ga2O3 p–n heterojunction detector incorporating an amorphous high-k dielectric BaTiO3 layer as the field-plate (FP) structure. By effectively redistributing the electric field, the FP implementation minimizes field crowding at device edges, reduces leakage current, and enhances carrier transport uniformity, thereby leading to significant background noise suppression. Consequently, the detector achieves an improved energy resolution of 4.3% for α-particle detection, surpassing the previously reported Ga2O3 radiation detectors. These findings deepen the fundamental understanding of noise mechanisms in β-Ga2O3 devices and demonstrate a robust field-engineering strategy for achieving low-noise and high-energy-resolution radiation detectors.

Article Details

Volume / Issue Vol. 127, Issue 5
Published August 04, 2025
ISSN 0003-6951
Publisher American Institute of Physics

Journal Info

Applied Physics Letters

American Institute of Physics

ISSN: 0003-6951 Physical Sciences

Authors (12)

X

X. Y. Pei

School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,

X

X. D. Meng

Institute of Nuclear Energy Safety Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences 2 , Hefei 230088,

L

L. Ren

Y

Y. C. Han

Institute of Nuclear Energy Safety Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences 2 , Hefei 230088,

N

N. Sun

W

W. Z. Xu

School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,

F

F.-F. Ren

School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,

D

D. W. Yan

School of Integrated Circuits, Jiangnan University 2 , Wuxi 214122,

Y

Y. Yang

S

S. L. Gu

School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,

R

R. Zhang

J

J. D. Ye

School of Electronic Science and Engineering, Nanjing University 1 , Nanjing 210023,