Wireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration

M Matija Jankovic (Chandra Family Department of Electrical and Computer Engineering) S Seungmin Kang (Department of Biomedical Engineering) S Sarnab Bhattacharya (Chandra Family Department of Electrical and Computer Engineering) J Jordon Kashanchi (Chandra Family Department of Electrical and Computer Engineering) J Jieting Wang (Department of Kinesiology and Health Education) K Kanika Deoli (Chandra Family Department of Electrical and Computer Engineering) T Tianda Huang (Chandra Family Department of Electrical and Computer Engineering) A Alex Johnson K Karina Ambani (Department of Biomedical Engineering) S Sangjun Kim (Department of Mechanical Engineering) P Pulin Wang (Stretch Med Inc) E Edward Coyle (Department of Kinesiology and Health Education) N Nanshu Lu

Abstract

Assessment of whole-body hydration (WBH) is crucial for health management and disease diagnosis. Traditional methods are invasive or require bulky equipment, making them impractical for mobile, continuous sensing. We present a wearable bioimpedance sensor with strategic electrode placement across the arm for noninvasive, continuous, and mobile WBH monitoring. Although whole-body bioimpedance is a proven method for indicating WBH, the effectiveness of local bioimpedance measurement has been unclear. Our finite element analysis demonstrated that with an optimized cross-arm sensing configuration, a strong linear relationship exists between arm bioimpedance and muscle electrical resistivity, confirming the utility of arm bioimpedance for assessing WBH given the well-established relationship between muscle electrical resistivity and body water. Our IRB-approved diuretic-induced dehydration study demonstrated a strong linear correlation between the increase of arm bioimpedance and the decrease in body weight due to water loss, with a Pearson correlation coefficient of 0.956 ± 0.033 among eight participants. Arm and whole-body demonstrated strong alignment, suggesting that arm bioimpedance measurements can reflect not only changes in WBH but also potentially absolute WBH status when compared against established population reference data. In a 24-h free-living experiment, the wireless, dry electrode-based, arm-conformable bioimpedance sensor continuously tracked dehydration and rehydration despite motions associated with daily activities. These results suggest that properly measured arm bioimpedance can serve as a surrogate for WBH, offering a reliable and accessible solution. The potential uses of this wearable technology range from improving personal wellness to enhancing professional sports and occupational safety.

Article Details

Volume / Issue Vol. 122, Issue 29
Published July 22, 2025
ISSN 0027-8424
Publisher National Academy of Sciences

Authors (13)

M

Matija Jankovic

Chandra Family Department of Electrical and Computer Engineering

S

Seungmin Kang

Department of Biomedical Engineering

S

Sarnab Bhattacharya

Chandra Family Department of Electrical and Computer Engineering

J

Jordon Kashanchi

Chandra Family Department of Electrical and Computer Engineering

J

Jieting Wang

Department of Kinesiology and Health Education

K

Kanika Deoli

Chandra Family Department of Electrical and Computer Engineering

T

Tianda Huang

Chandra Family Department of Electrical and Computer Engineering

A

Alex Johnson

K

Karina Ambani

Department of Biomedical Engineering

S

Sangjun Kim

Department of Mechanical Engineering

P

Pulin Wang

Stretch Med Inc

E

Edward Coyle

Department of Kinesiology and Health Education

N

Nanshu Lu