Why good quality water models have a surprisingly wide range of dielectric constants
Abstract
Simple water models with fixed partial charges, particularly 4-site models such as TIP4P/2005, TIP4P-FB, and OPC, have proven to be highly accurate in reproducing many experimental properties of liquid water. It is intriguing that dielectric constants of these models, together with those of popular 3-site models, such as SPC/E and TIP3P, cover a wide range of values, often very far from the experimental one. Here, we address the issue of the surprising insensitivity of the quality of a water model to its dielectric constant. We build upon our recently developed machine learning-assisted methodology for water model development to construct and analyze a large set of high-quality water models with dielectric constants varying from ∼45 to ∼75. We confirm the weak sensitivity of the water model quality on the dielectric constant in this broad range, with optimal values for classical 4-site fixed charge water models lying between 55 and 70. We also identified a set of correlations between parameters of high quality water models at a given value of the dielectric constant.
Article Details
Journal Info
The Journal of Chemical Physics
American Institute of Physics
Authors (3)
Víctor Cruces Chamorro
Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences , Flemingovo nám. 2, 16610 Prague 6,
Pavel Jungwirth
Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences , Flemingovo nám. 2, 16610 Prague 6,
Hector Martinez-Seara
Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences , Flemingovo nám. 2, 16610 Prague 6,