Impact of double-bolus tracking to individualize scan timing of the portal venous phase in preoperative computed tomography colonography angiography for right-sided colon cancer

Y Yoshiya Ohashi M Masaaki Miyo K Koichi Okuya E Emi Akizuki A Atsushi Hamabe A Ai Noda M Masayuki Ishii R Ryo Miura M Momoko Ichihara M Maho Toyota K Kohei Okamoto S Shun Hayasaka T Takeo Tanaka H Hiroyuki Takashima K Kohei Harada K Keishi Ogura I Ichiro Takemasa

Abstract

Aim In computed tomography colonography angiography (CTC-A), used for preoperative screening of right-sided colon cancer, the timing of venous phase imaging is conventionally determined by a fixed-delay time; however, the contrast effect may be insufficient because of individual differences in blood flow status. Therefore, we developed the double-bolus tracking (DBT) method to solve this issue. Method We compared the contrast effect and image quality of the portal venous systems between two methods of the conventional fixed-delay and DBT which utilizes low-dose monitoring to individualize venous scan timings. Data from 30 consecutive patients who underwent CTC-A for right-sided colon cancer using the DBT method were prospectively collected and compared with that from 30 consecutive patients who underwent the conventional fixed-delay method between August 2018 and July 2022. CT values of the portal vein, gastrocolic trunk, and middle colic veins were measured. Additionally, two gastrointestinal surgeons performed a five-point visual evaluation of the three-dimensional volume rendering image of the gastrocolic trunk. Results CT values in the DBT group were significantly higher than those in the fixed-delay group. (portal vein: 266.7 HU vs. 210.0 HU; p <  0.001, gastrocolic trunk: 251.6 HU vs. 191.0 HU; p <  0.001, middle colic vein: 257.2 HU vs. 190.1 HU; p <  0.001). Visual assessment of the gastrocolic trunk was significantly higher in the DBT group than that in the fixed-delay group (DBT, 3.6, 3.4; fixed-delay, 2.6, 2.8; p =  0.003, p =  0.044). Conclusion The DBT method can enhance the contrast effect of the portal venous systems and improve image quality.

Article Details

Journal PLoS ONE
Volume / Issue Vol. 20, Issue 3
Published March 25, 2025
Pages e0320630
ISSN 1932-6203
Publisher Public Library of Science

Journal Info

PLoS ONE

Public Library of Science

ISSN: 1932-6203 Open Access Health Sciences

Authors (17)

Y

Yoshiya Ohashi

M

Masaaki Miyo

K

Koichi Okuya

E

Emi Akizuki

A

Atsushi Hamabe

A

Ai Noda

M

Masayuki Ishii

R

Ryo Miura

M

Momoko Ichihara

M

Maho Toyota

K

Kohei Okamoto

S

Shun Hayasaka

T

Takeo Tanaka

H

Hiroyuki Takashima

K

Kohei Harada

K

Keishi Ogura

I

Ichiro Takemasa