First positronium lifetime imaging using 52Mn and 55Co with a plastic-scintillator-based PET scanner
Abstract
Abstract This study demonstrates the applicability of $$^{52}$$ Mn and $$^{55}$$ Co radionuclides for positronium imaging. Positronium Lifetime Imaging (PLI) extends positron emission tomography by using the lifetime of positronium atoms as a probe of tissue molecular architecture. However, its practical use requires $$\beta ^{+}$$ emitters that also provide an additional prompt $$\gamma$$ ray to mark the positron creation time. In this work, we report the first PLI measurements performed with $$^{52}$$ Mn and $$^{55}$$ Co using the modular J-PET. Four samples were studied in each experiment: two Certified Reference Materials (polycarbonate and fused silica) and two human tissues (cardiac myxoma and adipose). The selection of PLI events was based on the registration of two 511 keV annihilation photons and one prompt gamma in triple coincidence. From the resulting lifetime spectra we extracted the mean ortho-positronium lifetime $$\tau _{\text {oPs}}$$ and the mean positron lifetime $$\Delta T_{\text {mean}}$$ for each sample. The measured values of $$\tau _{\text {oPs}}$$ in polycarbonate using both isotopes matches well with the certified reference values. Furthermore, $$^{55}$$ Co reproduced identical results for fused-silica measurements at their respective uncertainty levels. In contrast, measurements with $$^{52}$$ Mn in fused silica show a minor deviation, which could be caused by the Parafilm spacer. In myxoma and adipose tissue, the reduced $$\tau _{\text {oPs}}$$ values are mainly linked to the long storage history of the samples rather than to the choice of isotope. Comparing peak-to-background ratios and spectral purity, $$^{55}$$ Co provides cleaner PLI data under the same experimental conditions. Although $$^{52}$$ Mn offers a longer half-life and a multi gamma cascade enhancing $$\beta ^{+}$$ + $$\gamma$$ coincidences, but at the expense of higher background. In this study, we demonstrate that the applied selection criteria on the data measured with the modular J-PET can be used for PLI studies even with radionuclides with complex decay patterns.
Article Details
Authors (48)
Manish Das
Sushil Sharma
Ermias Yitayew Beyene
Aleksander Bilewicz
Jarosław Choiński
Neha Chug
Catalina Curceanu
Eryk Czerwiński
Jakub Hajduga
Sharareh Jalali
Krzysztof Kacprzak
Tevfik Kaplanoglu
Łukasz Kapłon
Kamila Kasperska
Aleksander Khreptak
Grzegorz Korcyl
Tomasz Kozik
Karol Kubat
Deepak Kumar
Sumit Kumar Kundu
Anoop Kunimmal Venadan
Edward Lisowski
Filip Lisowski
Justyna Medrala-Sowa
Simbarashe Moyo
Wiktor Mryka
Szymon Niedźwiecki
Anand Pandey
Piyush Pandey
Szymon Parzych
Alessio Porcelli
Bartłomiej Rachwał
Martin Rädler
Narendra Rathod
Noman Razzaq
Axel Rominger
Kuangyu Shi
Magdalena Skurzok
Maciej Słotwiński
Anna Stolarz
Tomasz Szumlak
Pooja Tanty
Keyvan Tayefi Ardebili
Satyam Tiwari
Kavya Valsan Eliyan
Rafał Walczak
Ewa Ł. Stepień
Paweł Moskal