Feasibility and reliability of decentralized HIV-1 viral load monitoring on self-sampled blood
Abstract
Background Home-based blood self-sampling for HIV-1 viral load (VL) monitoring has the potential to alleviate pressure on healthcare systems by reducing clinic visits for people with HIV. This study evaluates the feasibility and reliability of HIV-RNA measurements in self-sampled blood and in viremic samples. Methods Between September 2024 and March 2025 participants were recruited at the outpatient clinic. Self-sampled blood was collected using the TassoPlus device at home and compared to conventional HIV-RNA testing from the same individual. Only samples containing a minimum volume of 200 μL plasma were deemed eligible for analysis. Also, 30 stored viremic samples (HIV-1 RNA 100–950 copies/mL) aliquoted into 200 μL volumes were included and compared to conventional HIV-RNA testing. The Alinity m HIV-1 assay (Abbott), validated for low plasma volumes, was used for all samples. Agreement was assessed using Pearson correlation and Bland-Altman analysis. Sample quality was assessed based on plasma volume and clotting. User-friendliness of the TassoPlus was evaluated through a questionnaire. Results Of the 62 participants (median age 56 [46–66]; 81% male), 63% (n = 38) returned the sample, yielding a mean plasma volume of 207 μL (range:10–550). Of these, 18 samples (29%) were excluded due to insufficient volume for analysis. HIV-RNA in both self-sampled and stored samples (n = 50), correlated with conventional samples (r = 0.800). However, in four low-volume viremic samples, HIV-RNA was <100 copies/mL, while conventional sampling detected 148, 260, 501 and 759 copies/mL, respectively. Bland-Altman analysis showed a mean difference of 0.08 log copies/mL (95%LOA:-0.79–0.95) between conventional sampled blood and low-volume samples (self-sampled/stored samples). No clotting was observed. Furthermore, 57% of participants expressed interest in using the TassoPlus, and 48% rated its usability as easy or very easy. Discussion Self-sampling with TassoPlus presents challenges, including high rates of unsuccessful sampling and potential failure to detect low-level viremia. Therefore, significant refinements are essential for reliable clinical use.
Article Details
Authors (6)
Kyra F. Mendes de Leon
Suzanne Jurriaans
Roos D. Klungers
Janke Schinkel
Department of Medical Microbiology and Infection Prevention, Amsterdam Infection and Immunity Institute, Amsterdam University Medical Center, University of Amsterdam
Pythia T. Nieuwkerk
Marc van der Valk