Evaluation of pre-analytical specimen rejection using Six Sigma metrics: A retrospective single-center study

X Xiuli Cheng H Haimiao Yu L Le Zhang B Biao Zhang Q Qin Wang

Abstract

Background Up to 60% of errors occur in the pre-analytical stage of laboratory testing, potentially impairing clinical decision-making. This study aimed to assess pre-analytical errors using Six Sigma metrics and identify underlying causes for quality improvement. Methods A retrospective analysis of pre-analytical sample errors was conducted over three years in a clinical laboratory. Errors were categorized, and Sigma values were calculated to assess quality. Trends over time were also analyzed. Results Of 2,068,074 samples, 2,214 (0.107%) were rejected. The top errors were clotted blood specimens (67.34%), insufficient volumes (8.22%), and cancelled test requests (6.28%), with Sigma values of 4.42, 5.25, and 5.32, respectively. The outpatient department performed best (Sigma = 5.47), while other wards required improvement. Conclusion Efforts are needed to reduce specimen rejection, particularly clotted samples, to enhance laboratory quality.

Article Details

Journal PLoS ONE
Volume / Issue Vol. 20, Issue 6
Published June 03, 2025
Pages e0324840
ISSN 1932-6203
Publisher Public Library of Science

Journal Info

PLoS ONE

Public Library of Science

ISSN: 1932-6203 Open Access Health Sciences

Authors (5)

X

Xiuli Cheng

H

Haimiao Yu

L

Le Zhang

B

Biao Zhang

Q