Engineered Perfusable Hepatic Fibrosis Model via Embedded Sacrificial Bioprinting Recapitulates Stiffness‐Driven Fibrogenesis

W Weikang Lv (State Key Laboratory of Fluid Power and Mechatronic Systems Zhejiang University Hangzhou China) T Tuya Naren (State Key Laboratory of Fluid Power and Mechatronic Systems Zhejiang University Hangzhou China) A Abdellah Aazmi (State Key Laboratory of Fluid Power and Mechatronic Systems Zhejiang University Hangzhou China) H Haoran Yu (Nanjing University , , ,) Y Yujun Wang (State Key Laboratory of Chemical Engineering and Low-Carbon Technology, Department of Chemical Engineering) J Jie Ying Lee (State Key Laboratory of Fluid Power and Mechatronic Systems Zhejiang University Hangzhou China) M Mengfei Yu (Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China (B.-Y.C., H.Z., M.Y., Q.C., S.-Z.D.).) J Junjun Jia (Division of Hepatobiliary and Pancreatic Surgery Department of Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China) X Xiuxiu Jiang (Zhejiang Provincial Clinical Research Center For Gynecology Zhejiang Key Laboratory of Maternal and Infant Health Department of Family Planning Women's Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China) H Huayong Yang (State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou, China.) L Liang Ma

Abstract

ABSTRACT Hepatic fibrosis, as the common pathological endpoint of chronic liver diseases, is characterized by a self‐perpetuating vicious cycle comprising extracellular matrix (ECM) driven liver tissue stiffening and sustained hepatic stellate cell (HSC) activation. Although existing studies have simulated fibrotic microenvironments using 2D models with tunable matrix stiffness or static 3D cultures, these models lack engineered hepatic sinusoidal vasculature and dynamic mechanical stimulation within 3D ECM contexts. This study employed embedded sacrificial bioprinting to construct functional liver sinusoid‐mimetic vascular networks within hydrogel matrix of precisely tunable elastic modulus, establishing a dynamically perfused in vitro liver fibrosis model. Experimental validation demonstrated that matrix stiffness directly drives HSC activation, inducing marked myofibroblastic transdifferentiation. Furthermore, compared to static models, 3D dynamic perfusion significantly enhanced hepatocyte sensitivity to high‐stiffness matrix, more accurately replicating the functional decline of hepatocytes in fibrotic microenvironments observed in vivo. More critically, the biomimetic in vitro platform established in this study presents a potential avenue for evaluating pharmacotherapeutic interventions against liver fibrosis. Through targeted inhibition of key signaling hubs, we achieved partial reversal of HSC activation on stiff matrix and partial recovery of liver tissue function. Overall, by simultaneously integrating matrix stiffness modulation, 3D multicellular interactions, and hemodynamic stimulation, this work effectively addresses the insufficient responsiveness of hepatocytes to mechanical cues in conventional models due to inadequate mechanical stimulation. This approach provides a robust framework for faithfully recapitulating the pathophysiological progression of liver fibrosis in vitro through precise tuning of ECM mechanical properties, thereby offering a promising platform for future drug screening and therapeutic assessment.

Article Details

Volume / Issue Vol. 38, Issue 13
Published March 01, 2026
ISSN 0935-9648
Publisher Unknown Publisher

Journal Info

Advanced Materials

Unknown Publisher

ISSN: 0935-9648 Physical Sciences

Authors (11)

W

Weikang Lv

State Key Laboratory of Fluid Power and Mechatronic Systems Zhejiang University Hangzhou China

T

Tuya Naren

State Key Laboratory of Fluid Power and Mechatronic Systems Zhejiang University Hangzhou China

A

Abdellah Aazmi

State Key Laboratory of Fluid Power and Mechatronic Systems Zhejiang University Hangzhou China

H

Haoran Yu

Nanjing University , , ,

Y

Yujun Wang

State Key Laboratory of Chemical Engineering and Low-Carbon Technology, Department of Chemical Engineering

J

Jie Ying Lee

State Key Laboratory of Fluid Power and Mechatronic Systems Zhejiang University Hangzhou China

M

Mengfei Yu

Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China (B.-Y.C., H.Z., M.Y., Q.C., S.-Z.D.).

J

Junjun Jia

Division of Hepatobiliary and Pancreatic Surgery Department of Surgery The First Affiliated Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China

X

Xiuxiu Jiang

Zhejiang Provincial Clinical Research Center For Gynecology Zhejiang Key Laboratory of Maternal and Infant Health Department of Family Planning Women's Hospital Zhejiang University School of Medicine Hangzhou Zhejiang Province China

H

Huayong Yang

State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou, China.

L

Liang Ma