DNTB: Dual-branch network model based on transformer and Bi-LSTM for energy consumption prediction in building chiller systems

A Andong Chen M Mingtao Wu (Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, China) C Cheng Chen C Chen Chen Y Yong Huang (National Laboratory of Solid State Microstructures, School of Physics) X Xiaoyi Lv

Abstract

Accurate prediction of chiller energy consumption is crucial for reducing building energy consumption. In this study, an innovative dual-branch network architecture DNTB (A Dual-Branch Network Model Based on Transformer and Bi-LSTM for Energy Consumption Prediction in Building Chiller Systems) was proposed to address the problems of insufficient long-term dependency modeling and noise sensitivity in current prediction models. The research goal is to develop a prediction model that can simultaneously process temporal features and global dependencies. The basic principle is to utilize the complementary characteristics of Transformer and Bi-LSTM. Transformer is sensitive to data noise and Bi-LSTM is weak in capturing long-term sequence information. It can better capture the temporal information of chiller energy consumption data and well model the relationship between variables such as chilled water, building load, chiller temperature, humidity, dew point and chiller energy consumption. In order to prove the effectiveness and generalization ability of the model, experiments were carried out on long-term and short-term tasks of chiller energy consumption prediction. The long-term prediction results had MSE (mean absolute error) of 0.0051, RMSE (mean square error) of 0.0605, and R2 (coefficient of determination) of 0.8031. The short-term prediction results had MSE of 0.0080, RMSE of 0.0738, and R2 of 0.6717. The experimental results indicate that DNTB performs excellently in both long-term and short-term chiller energy consumption prediction, making it a robust framework for chiller energy consumption prediction. The introduction of DNTB enriches the diversity of empirical model algorithms.

Article Details

Journal PLoS ONE
Volume / Issue Vol. 20, Issue 10
Published October 03, 2025
Pages e0330187
ISSN 1932-6203
Publisher Public Library of Science

Journal Info

PLoS ONE

Public Library of Science

ISSN: 1932-6203 Open Access Health Sciences

Authors (6)

A

Andong Chen

M

Mingtao Wu

Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, China

C

Cheng Chen

C

Chen Chen

Y

Yong Huang

National Laboratory of Solid State Microstructures, School of Physics

X

Xiaoyi Lv