Diagnostic limitations in advanced stage peripheral arterial disease in a cadaveric study comparing photon-counting and energy-integrating CT detectors

V Viktor Hartung H Henner Huflage A Anne Marie Augustin S Sven Lichthardt D Dominik Peter F Florian Kleefeldt S Süleyman Ergün T Thorsten Alexander Bley J Jan-Peter Grunz P Philipp Gruschwitz

Abstract

Abstract To evaluate the limits of 1st-generation dual-source photon-counting detector CT (PCD-CT) and 3rd-generation dual-source energy-integrating-detector (EID-CT) regarding imaging of advanced stage peripheral arterial disease (ASPAD) of the femoral runoff. One human cadaver with ASPAD of the superficial femoral arteries was surgically prepared to establish continuous extracorporeal perfusion of the right upper leg. In addition to one stent already in place, three more stents were deployed in positions with severe calcification and stenosis to create thirteen different scenarios of ASPAD. CT angiographies with different radiation dose (CTDIvol 10, 5, 3 mGy) and matching convolution kernels were performed with PCD-CT and EID-CT. In-stent lumen visibility, signal-to-noise ratio (SNR), and luminal attenuation were assessed quantitatively. Results were compared using analyses of variance with a PCD-CT maximum dose and resolution scan (96 mGy, BV89) serving as standard of reference. Highest and lowest stent lumen visibility was observed with PCD-CT BV76 (97 ± 2%) and EID BV40 (77 ± 5%), respectively. Severe stent underexpansion in conjunction with heavy calcification resulted in the worst lumen visibility. PCD-CT displayed superior dose efficiency, yielding comparable SNR at 3 mGy to EID-CT at 10 mGy (p = 0.27). Luminal attenuation was higher for PCD-CT regardless of dose and reconstruction settings (max. 369 ± 19 HU, BV76, 5 mGy vs. 329 ± 12 HU for EID, BV59, 5 mGy; p < 0.001). PCD-CT realises substantially higher image quality than EID-CT, thereby enhancing assessment of the femoral vasculature in ASPAD. Furthermore, this indicates substantial radiation dose and contrast agent volume saving potential. Both scanners show limitations in very low luminal diameters.

Article Details

Volume / Issue Vol. 15, Issue 1
Published February 26, 2025
ISSN 2045-2322
Publisher Nature Portfolio

Journal Info

Scientific Reports

Nature Portfolio

ISSN: 2045-2322 Open Access Life Sciences

Authors (10)

V

Viktor Hartung

H

Henner Huflage

A

Anne Marie Augustin

S

Sven Lichthardt

D

Dominik Peter

F

Florian Kleefeldt

S

Süleyman Ergün

T

Thorsten Alexander Bley

J

Jan-Peter Grunz

P

Philipp Gruschwitz