DEVELOPMENT AND VALIDATION OF THE UV-SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF TETRAHYDROCURCUMIN
Abstract
The main objective is to develop and validate the UV-spectrophotometric method for the estimation of Tetrahydrocurcumin as per ICH guidelines. Materials and Methods: A simple, rapid, accurate, and economical UV-spectrophotometric method has been developed for the estimation of tetrahydrocurcumin. Results: Theλ max of tetrahydrocurcumin was found to be 280nm. The drug follows linearity in the concentration range 2-12 µg mL-1 with a correlation coefficient value of 0.9975. The accuracy of the method was checked by recovery experiment performed at three different levels, i.e., 50%,100% and 120%. The % recovery was found to be in the ranged between 97.81-101.39 with < 1 %RSD, thereby indicating the low variability and a strong agreement between experimental and true values. Ruggedness of the proposed method was studied with the help of two analysts. Conclusion: The above method was a rapid tool for routine analysis of tetrahydrocurcumin.
Article Details
Journal Info
Tropical Journal of Pharmaceutical and Life Sciences
Jadoun Science Publishing Group
Authors (3)
Jorapur Devaki
Dr Satish Pavuluri
Savalgi Sonali