Design and experimental study of a precision fluid hill-drop planter for maize

Z Zhengwei Zhang L Lang Zhou A Anping Ji Z Zhaoran Sun G Guangyao Zhu X Xiong Chen (State Key Laboratory of Chemistry for NBC Hazards Protection, College of Chemistry) J Junhao Pi C Chenxi Yang H Haoxuan Chen Z Zhenyu Yang H Hu Tian (State Key Laboratory of Fluorine and Nitrogen Chemistry and Advanced Materials, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China)

Abstract

The study presents the design of a precision maize hill-drop dibbler based on fluid control and zero-speed seeding theory, developed to overcome challenges of poor planting precision, seed damage, limited terrain adaptability, and low water-use efficiency in maize cultivation across the hilly regions of Southwest China. To this end, a novel precision fluid hill-drop planter was designed, integrating fluid control with zero-speed seeding theory. The device employs a seed-liquid separation and terminal mixing design, where a crank-connecting rod-driven piston pump ensures precise fluid delivery. A direct comparative experimental framework was established, evaluating the proposed planter against a traditional spoon-wheel seeder under identical bench-test conditions. Performance was assessed through CFD-DEM coupled simulation and systematic experiments across multiple dimensions: seeding precision (qualified, multiple, and miss index), hill-forming characteristics, and fluid performance (water application per hill, seed bounce distance). The comparative results demonstrated that within an operating speed range of 1.2 ~ 1.6 m/s, the new planter achieved a qualified index exceeding 91%, a significant improvement of 12.5% over the conventional device. The seed bounce distance was controlled within 5.4 mm, representing a 63.2% reduction. Furthermore, the system exhibited excellent operational stability, with a coefficient of variation for water application per hill of less than 2% and a check valve leakage rate below 3%. Through collaborative parameter optimization, breakthrough indicators were achieved: a 94.8% seed-water coincidence rate and a hill spacing deviation of no more than 1.0%. This research validates the proposed planter’s superior performance and reliability, providing an effective technical solution to enhance sowing uniformity and water-use efficiency in complex terrain.

Article Details

Journal PLoS ONE
Volume / Issue Vol. 20, Issue 12
Published December 04, 2025
Pages e0337887
ISSN 1932-6203
Publisher Public Library of Science

Journal Info

PLoS ONE

Public Library of Science

ISSN: 1932-6203 Open Access Health Sciences

Authors (11)

Z

Zhengwei Zhang

L

Lang Zhou

A

Anping Ji

Z

Zhaoran Sun

G

Guangyao Zhu

X

Xiong Chen

State Key Laboratory of Chemistry for NBC Hazards Protection, College of Chemistry

J

Junhao Pi

C

Chenxi Yang

H

Haoxuan Chen

Z

Zhenyu Yang

H

Hu Tian

State Key Laboratory of Fluorine and Nitrogen Chemistry and Advanced Materials, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China