Comparable performance of 3D and 2D anterior segment optical coherence tomography in predicting intraocular pressure reduction following cataract surgery

S Sunee Chansangpetch P Phichayut Phinyo J Jayanton Patumanond J Janejit Choovuthayakorn S Shan C Lin

Abstract

Purpose To develop predictive models using three-dimensional (3D) and conventional two-dimensional (2D) anterior-segment optical coherence tomography (AS-OCT) parameters for intraocular pressure (IOP) reduction following phacoemulsification in glaucoma and non-glaucoma cohorts. Methods This prospective study included patients with and without glaucoma who underwent phacoemulsification. Preoperative predictors of 1-month IOP reduction, including clinical, ocular biometry, and AS-OCT (CASIA2) parameters, were analyzed. 3D AS-OCT measurements were assessed in two approaches: (1) averaging 360-degree values and (2) estimating circumferential areas or volumes. 2D variables were obtained from horizontal cross-sectional images. Model selection with least absolute shrinkage and selection operator (LASSO) for 2D and 3D variables was performed separately. R-squared (R²) used to represent model accuracy. The performance was validated by bootstrap resampling. Results A total of 130 eyes (64 glaucoma, 66 non-glaucoma) from 103 patients were included. The average IOP change was −1.20 ± 3.29 mmHg. Preoperative IOP (preIOP) was the strongest single predictor across all models. In the entire cohort, the final models showed moderate predictability (R² 38% for 3D and 36% for 2D; optimism-corrected R² 31% for both). In glaucoma eyes, models incorporating AS-OCT angle status and anterior chamber width achieved R² values of 36% (3D) and 38% (2D), with optimism-corrected R² of 27% (3D) and 28% (2D). In non-glaucoma eyes, both 3D and 2D models showed higher predictability (R² 53%, optimism-corrected R² 45%), with final predictors incorporating AS-OCT anterior chamber area and iris thickness. Both 3D and 2D models significantly outperformed the reference preIOP models across all cohorts (all p > 0.05). Conclusions AS-OCT parameters improved the predictability of IOP reduction after phacoemulsification, with notably better performance in non-glaucoma eyes. 2D and 3D models showed comparable predictive ability.

Article Details

Journal PLoS ONE
Volume / Issue Vol. 21, Issue 3
Published March 25, 2026
Pages e0345582
ISSN 1932-6203
Publisher Public Library of Science

Journal Info

PLoS ONE

Public Library of Science

ISSN: 1932-6203 Open Access Health Sciences

Authors (5)

S

Sunee Chansangpetch

P

Phichayut Phinyo

J

Jayanton Patumanond

J

Janejit Choovuthayakorn

S

Shan C Lin