An exceptionally conductive hydrogel for all-organic, ultraflexible, and chronic neural interfaces

R Ruiqi Zhu (State Key Laboratory of Coordination Chemistry, Chemistry and Biomedicine Innovation Center (ChemBIC), Frontier Interdisciplinary Science Research Center, School of Chemistry and Chemical Engineering) Z Zhengwei Hu (Chinese Academy of Sciences Key Laboratory of Brain Connectome and Manipulation, the Brain Cognition and Brain disease Institute, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences Shenzhen-Hong Kong Institute of Brain Science-Shenzhen Fundamental Research Institutions) Z Zirui Lou (Institute of Materials Research, Shenzhen International Graduate School, Tsinghua University) F Fei Xie (State Key Laboratory of Catalysis, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023, China) S Shuainan Zhao (Chinese Academy of Sciences Key Laboratory of Brain Connectome and Manipulation, Shenzhen-Hong Kong Institute of Brain Science, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences) X Xuechen Jiao (National Synchrotron Radiation Laboratory) J Jianyu Wang K Kenjiro Fukuda (Thin-Film Device Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan) X Xiaodong Chen (Innovative Centre for Flexible Devices (iFLEX), Max Planck-NTU Joint Lab for Artificial Senses, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Republic of Singapore) W Wenping Hu H Hui-Ming Cheng (Institute of Technology for Carbon Neutrality, Shenzhen Key Laboratory of Energy Materials for Carbon Neutrality, Shenzhen Institutes of Advanced Technology) X Xiaojian Li (Anhui Province Key Laboratory for Control and Applications of Optoelectronic Information Materials) T Takao Someya (Thin-Film Device Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan) X Xiaomin Xu (Curtin Centre for Advanced Energy Materials and Technologies (CAEMT), Western Australian School of Mines (WASM))

Abstract

Chronic neural interfaces are essential for advancing brain–computer interfaces, neuroprosthetics, and neuromodulation technologies. However, a long-standing trade-off between performance and longevity persists due to the scarcity of materials that simultaneously achieve superior electrical performance, mechanical compliance, and biocompatibility. Here, we overcome this limitation with an all-organic, ultraflexible electrocorticography (ECoG) design that features a thickness of only 9 µm, achieving low electrode–tissue impedance and durability in vivo. Central to this design is a conductive hydrogel featuring an interfacial percolation (CHIP) microstructure, with tunable hydration levels and softness, achieving a highest in-plane electrical conductivity of 2,512 S cm –1 . We further developed an in-plane swelling control with a dry, soft-protective etching strategy that preserves the structural integrity during hydrogel processing. The resulting all-organic ECoG array conforms to the cortical surface, minimizing foreign body response and providing exceptional signal quality, with the longest record up to 550 d.

Article Details

Volume / Issue Vol. 123, Issue 18
Published May 05, 2026
ISSN 0027-8424
Publisher National Academy of Sciences

Authors (14)

R

Ruiqi Zhu

State Key Laboratory of Coordination Chemistry, Chemistry and Biomedicine Innovation Center (ChemBIC), Frontier Interdisciplinary Science Research Center, School of Chemistry and Chemical Engineering

Z

Zhengwei Hu

Chinese Academy of Sciences Key Laboratory of Brain Connectome and Manipulation, the Brain Cognition and Brain disease Institute, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences Shenzhen-Hong Kong Institute of Brain Science-Shenzhen Fundamental Research Institutions

Z

Zirui Lou

Institute of Materials Research, Shenzhen International Graduate School, Tsinghua University

F

Fei Xie

State Key Laboratory of Catalysis, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023, China

S

Shuainan Zhao

Chinese Academy of Sciences Key Laboratory of Brain Connectome and Manipulation, Shenzhen-Hong Kong Institute of Brain Science, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences

X

Xuechen Jiao

National Synchrotron Radiation Laboratory

J

Jianyu Wang

K

Kenjiro Fukuda

Thin-Film Device Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan

X

Xiaodong Chen

Innovative Centre for Flexible Devices (iFLEX), Max Planck-NTU Joint Lab for Artificial Senses, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Republic of Singapore

W

Wenping Hu

H

Hui-Ming Cheng

Institute of Technology for Carbon Neutrality, Shenzhen Key Laboratory of Energy Materials for Carbon Neutrality, Shenzhen Institutes of Advanced Technology

X

Xiaojian Li

Anhui Province Key Laboratory for Control and Applications of Optoelectronic Information Materials

T

Takao Someya

Thin-Film Device Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan

X

Xiaomin Xu

Curtin Centre for Advanced Energy Materials and Technologies (CAEMT), Western Australian School of Mines (WASM)