Accurate alpha-particle stopping power measurements in graphenic carbon foils and their application to high-precision, non-destructive areal density determination

K Konstantina Botsiou S Sivaji Purushothaman H Hans Geissel T Timo Dickel J Joachim Enders E Emma Haettner D David J. Morrissey M Maxim Saifulin C Christoph Scheidenberger M Marilena Tomut H Helmut Weick J Jianwei Zhao (Shenzhen HUASUAN Technology Co., Ltd)

Abstract

Abstract A precise, non-destructive method for determining the areal density of thin graphenic carbon (GC) foils via alpha-particle energy loss is presented. Two types of GC foils — sourced from KETEK GmbH and Applied Nanotech Inc. — were investigated using a three-isotope mixed alpha source emitting particles in the 5.0–5.8  $$\textrm{MeV}$$ range. Both foils have similar nominal areal densities of approximately $$0.2\,\mathrm {mg\,cm^{-2}}$$ , but differ slightly in chemical composition and microstructure. High-resolution alpha spectroscopy yielded energy-loss measurements with relative uncertainties below 1%. The uncertainty of the extracted areal densities and stopping powers is dominated by the determination of foil mass, area and composition metrology, rather than by the alpha-energy-loss measurement itself. Experimental stopping powers were obtained by combining the measured energy loss with independently determined foil masses and areas, and were compared with established stopping-power models. A modified Bethe formalism incorporating Barkas and Bloch corrections, together with an empirically adjusted mean excitation energy $$I_\textrm{adj}$$ , provided the most consistent description of the data across the investigated energy range. The resulting values were $$(73 \pm 2)\,\textrm{eV}$$ for the KETEK foil and $$(85 \pm 3)\,\textrm{eV}$$ for the Applied Nanotech foil. The fitted stopping-power curves indicate a systematic difference between the two GC foils, consistent with their differing compositions and microstructures. Because the stopping-power model is calibrated against the same reference foils, however, this interpretation is model-dependent and requires further validation using independently characterised samples. While the method is well suited to thin foils, angular straggling and the non-linear energy dependence of the stopping power may limit its applicability beyond the thin-target approximation. The reported stopping-power data are relevant for benchmarking Monte Carlo simulations and modelling energy deposition in carbon-based materials, with applications in accelerator technology and radiopharmaceutical research. In medical physics, stopping power is closely related to linear energy transfer, which governs the biological effectiveness of alpha-emitting isotopes in targeted therapies.

Article Details

Volume / Issue Vol. 16, Issue 1
Published June 14, 2026
ISSN 2045-2322
Publisher Nature Portfolio

Journal Info

Scientific Reports

Nature Portfolio

ISSN: 2045-2322 Open Access Life Sciences

Authors (12)

K

Konstantina Botsiou

S

Sivaji Purushothaman

H

Hans Geissel

T

Timo Dickel

J

Joachim Enders

E

Emma Haettner

D

David J. Morrissey

M

Maxim Saifulin

C

Christoph Scheidenberger

M

Marilena Tomut

H

Helmut Weick

J

Jianwei Zhao

Shenzhen HUASUAN Technology Co., Ltd