Abstract WE572: Intravascular ultrasound and hemodynamics in stenotic lesions of arteriovenous fistulas or grafts in patients on hemodialysis

S Saran Lotfollahzadeh J Jeffrey Siracuse (Boston University, Chestnut Hill, Massachusetts, United States) A Alik Farber (Boston University School of Medicine, Boston) V Vijaya Kolachalama (BU SCHOOL OF MEDICINE, Boston, Massachusetts, United States) S Suvranu Ganguli (Boston University School of Medicin, Boston, Massachusetts, United States) V Vipul Chitalia

Abstract

Background: Chronic kidney disease (CKD) is a major public health crisis. In the US, one out of seven people has CKD. Of these, over 815,000 people have end-stage kidney disease (ESKD). Approximately 550,000 people undergo hemodialysis treatment in the US. Arteriovenous (AV) vascular accesses, such as arteriovenous fistulas (AVFs) or arteriovenous grafts (AVGs), are required for hemodialysis. Conventional angiography remains the standard diagnostic modality for access dysfunction, but its geometric accuracy is limited. Intravascular ultrasound (IVUS) offers superior lesion detection, yet its accuracy remains uncertain. Using three-dimensional (3D) printed vascular conduits as reference standards, we assessed the accuracy of IVUS versus angiography, hypothesizing that complex conduit geometry, quantified by Gaussian curvature, would exacerbate angiographic error. Methods: Clinically relevant AV access geometries were modeled with computer-aided design (CAD) and fabricated using 3D printing. Lumen diameters were measured by contrast angiography and IVUS, and then compared against CAD dimensions. Conduit geometry was characterized using finite element–based Gaussian curvature mapping. Statistical analyses examined measurement errors, their relationship to geometric complexity and differences across imaging modalities. Results: IVUS demonstrated significantly lower measurement error, particularly in stenotic segments with greater than 50% luminal narrowing. This high-grade stenosis frequently coincided with regions of high positive or negative Gaussian curvature, reflecting the complex geometry of the conduit. In such regions, angiography consistently underestimated lumen diameter, with error magnitude increasing in tortuous segments. IVUS measurements closely approximated CAD ground truth, retaining accuracy even in severe stenosis. For mild stenosis (<50%) and aneurysmal dilatations, both modalities performed comparably. Conclusion: Geometric complexity directly contributes to modality-specific error. Angiography systematically underestimates lumen dimensions in complex, stenotic regions, while IVUS preserves accuracy. These findings establish IVUS as the more reliable modality for evaluating AV access dysfunction and support its integration into routine practice for guiding intervention in AV access stenosis.

Article Details

Journal Circulation
Volume / Issue Vol. 153, Issue Suppl_1
Published March 24, 2026
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (6)

S

Saran Lotfollahzadeh

J

Jeffrey Siracuse

Boston University, Chestnut Hill, Massachusetts, United States

A

Alik Farber

Boston University School of Medicine, Boston

V

Vijaya Kolachalama

BU SCHOOL OF MEDICINE, Boston, Massachusetts, United States

S

Suvranu Ganguli

Boston University School of Medicin, Boston, Massachusetts, United States

V

Vipul Chitalia