Abstract TH852: Real-Time Mitral Valve Segmentation on 3-D Transesophageal Echocardiography with Quality Assurance for Intraoperative Decision Support
Abstract
Background: Intraoperative decision making for mitral valve repair relies on rapid, reliable assessment of leaflet anatomy from three-dimensional transesophageal echocardiography (3-D TEE). Current workflows depend on manual or semi-automated segmentation that is time-consuming, operator-dependent, and inconsistently exportable to meshes for sizing and simulation. Hypothesis: We hypothesize that an AI-powered 3-D TEE segmentation pipeline with single-pass, entropy-based quality assurance (QA) will deliver clinically actionable, real-time leaflet segmentations and clean mesh exports, supporting intraoperative repair planning and device sizing. Methods: We trained a transformer-based 3-D segmentation model (Swin-UNETR) on the MVSeg-2023 TEE dataset that consists of 150 end-diastolic TEE volumes. Volumes underwent intensity normalization, isotropic resampling to 0.6-mm voxels, and foreground cropping before inference. Temperature-scaled logits were converted to voxel-wise Shannon-entropy maps, a case-level quality score was thresholded using the validation set to gate low-confidence outputs. The primary endpoint was class-averaged Dice overlap for anterior and posterior leaflets. Secondary endpoints included boundary error (95th-percentile Hausdorff distance (HD95), average symmetric surface distance (ASSD)), mesh quality (non-manifold-edge rate), and end-to-end latency. Results: On the held-out test set, class-averaged Dice was high (0.832 ± 0.051). Boundary errors were low (HD95 = 4.2 ± 2.1 mm and ASSD = 0.39 ± 0.013 mm). Meshes were topologically clean (non-manifold edges = 0.21 ± 0.07%) and exported in real time (end-to-end time = 122 ± 35 ms with segmentation time = 104 ± 34 ms and peak GPU memory ≈4.0 GB). All test cases passed the entropy-based QA gate; within accepted cases, entropy and Dice were uncorrelated (Pearson correlation coefficient r = 0.016, p-value = 0.92). Across all test studies, the pipeline produced standardized leaflet masks and mesh exports automatically, enabling immediate downstream intraoperative support. Conclusions: Our transformer pipeline for TEE mitral-leaflet segmentation achieved high overlap accuracy, clean instant meshes, and real-time performance while providing a transparent QA signal, supporting its potential for intraoperative guidance and downstream computational modeling. Next steps include multi-vendor, multi-pathology external validation and extension to temporally consistent 4-D TEE.
Article Details
Authors (14)
Dang Nguyen
Minh Le
Heath Rutledge-Jukes
Washington University in St. Louis School of Medicine, St. Louis, Missouri, United States
Cameron Sabet
Georgetown University School of Medicine, Washington, District of Columbia, United States
Triet Nguyen
North Carolina A&T State University, Greensboro, North Carolina, United States
Perisa Ashar
Duke University, Durham, North Carolina, United States
Huong Ngoc Lien Dao
North Carolina A&T State University, Greensboro, North Carolina, United States
Ketan Tamirisa
Washington University in St. Louis School of Medicine, St. Louis, Missouri, United States
Pallavi Jonnalagadda
Washington University in St. Louis School of Medicine, St. Louis, Missouri, United States
Tam Tran
Olabiyi Olaniran
North Carolina A&T State University, Greensboro, North Carolina, United States
Tran Quoc Khanh Le
North Carolina A&T State University, Greensboro, North Carolina, United States
Phat Huynh
North Carolina A&T State University, Greensboro, North Carolina, United States
Jacques Kpodonu
Harvard Medical School, Boston, Massachusetts, United States