Abstract Sun805: Relationship between ventriculoarterial coupling and hemodynamics using active decompression and impedance threshold device during automated head-up CPR
Abstract
Background: Ventriculo-arterial (VA) coupling characterizes the interaction between the cardiac function and the arterial circulation afterload and reflects cardiovascular performance. We found, for the first time, that there is a significant VA decoupling with conventional CPR, which was ameliorated by automated head-up (AHUP)-CPR using active compression-decompression (ACD), impedance threshold device (ITD) as well as head and thorax elevation. Research Questions: How does the degree of active decompression (AD) influence VA coupling and its association with hemodynamic and perfusion outcomes during AHUP-CPR? Methods: Farm pigs (~40 kg) were intubated, ventilated, and monitored for hemodynamics, including end-tidal CO2 (ETCO2), and pressure-volume loops in right (RV | n=10) and left (LV | n =4) ventricles. After 10 minutes of untreated ventricular fibrillation, CPR started with 2 minutes each of C-CPR, ACD+ITD, and AHUP-CPR at 3 cm elevation. At minute 15, AD was paused, then resumed incrementally up to 4 cm. Statistical analysis was performed using a mixed-effects model to evaluate the effects of incremental AD on VA coupling, and a Spearman correlation to explore the relationship between VA coupling and hemodynamics. Results: Full AD (3cm or more) resulted in significantly enhanced VA coupling compared to no AD (p<0.05 in both ventricles) or minimal AD (1cm | p<0.05 RV and p=0.24 LV). Improved RV and LV VA coupling with full AD was associated with higher SV in both ventricles, as well as higher aortic pressures, and coronary and cerebral perfusions (table 1 and figure 1). Optimized VA coupling was also correlated with enhanced compression efficiency, which led to end compression volumes as a result of more efficient cardiac output. Conclusion: Full AD (3cm or more) when used with ITD during AHUP-CPR leads to optimal VA circulation. Optimized VA coupling in both ventricles resulted in enhanced cardiac filling and output, and subsequently, increased systemic, coronary and cerebral perfusion pressures. RV showed a different pattern to LV, likely due to its different load and contractile efficiency.
Article Details
Authors (7)
Pouria Poorzand
Lehigh Valley Health Network, Allentown, Pennsylvania, United States
Bayert Salverda
Hennepin Healthcare Research Inst., Minneapolis, Minnesota, United States
Johanna Moore
Hennepin County Medical Center, Minneapolis, Minnesota, United States
Anja Metzger
UNIVERSITY OF MINNESOTA, Lake Elmo, Minnesota, United States
Mithun Suresh
M Health Fairview, Vadnais Heights, Minnesota, United States
Nicolas Segond
CHU Grenoble Alpes, Grenoble, France
Keith Lurie
UNIV OF MINNESOTA HLTH CTR, Minneapolis, Minnesota, United States