Abstract Sun805: Relationship between ventriculoarterial coupling and hemodynamics using active decompression and impedance threshold device during automated head-up CPR

P Pouria Poorzand (Lehigh Valley Health Network, Allentown, Pennsylvania, United States) B Bayert Salverda (Hennepin Healthcare Research Inst., Minneapolis, Minnesota, United States) J Johanna Moore (Hennepin County Medical Center, Minneapolis, Minnesota, United States) A Anja Metzger (UNIVERSITY OF MINNESOTA, Lake Elmo, Minnesota, United States) M Mithun Suresh (M Health Fairview, Vadnais Heights, Minnesota, United States) N Nicolas Segond (CHU Grenoble Alpes, Grenoble, France) K Keith Lurie (UNIV OF MINNESOTA HLTH CTR, Minneapolis, Minnesota, United States)

Abstract

Background: Ventriculo-arterial (VA) coupling characterizes the interaction between the cardiac function and the arterial circulation afterload and reflects cardiovascular performance. We found, for the first time, that there is a significant VA decoupling with conventional CPR, which was ameliorated by automated head-up (AHUP)-CPR using active compression-decompression (ACD), impedance threshold device (ITD) as well as head and thorax elevation. Research Questions: How does the degree of active decompression (AD) influence VA coupling and its association with hemodynamic and perfusion outcomes during AHUP-CPR? Methods: Farm pigs (~40 kg) were intubated, ventilated, and monitored for hemodynamics, including end-tidal CO2 (ETCO2), and pressure-volume loops in right (RV | n=10) and left (LV | n =4) ventricles. After 10 minutes of untreated ventricular fibrillation, CPR started with 2 minutes each of C-CPR, ACD+ITD, and AHUP-CPR at 3 cm elevation. At minute 15, AD was paused, then resumed incrementally up to 4 cm. Statistical analysis was performed using a mixed-effects model to evaluate the effects of incremental AD on VA coupling, and a Spearman correlation to explore the relationship between VA coupling and hemodynamics. Results: Full AD (3cm or more) resulted in significantly enhanced VA coupling compared to no AD (p<0.05 in both ventricles) or minimal AD (1cm | p<0.05 RV and p=0.24 LV). Improved RV and LV VA coupling with full AD was associated with higher SV in both ventricles, as well as higher aortic pressures, and coronary and cerebral perfusions (table 1 and figure 1). Optimized VA coupling was also correlated with enhanced compression efficiency, which led to end compression volumes as a result of more efficient cardiac output. Conclusion: Full AD (3cm or more) when used with ITD during AHUP-CPR leads to optimal VA circulation. Optimized VA coupling in both ventricles resulted in enhanced cardiac filling and output, and subsequently, increased systemic, coronary and cerebral perfusion pressures. RV showed a different pattern to LV, likely due to its different load and contractile efficiency.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (7)

P

Pouria Poorzand

Lehigh Valley Health Network, Allentown, Pennsylvania, United States

B

Bayert Salverda

Hennepin Healthcare Research Inst., Minneapolis, Minnesota, United States

J

Johanna Moore

Hennepin County Medical Center, Minneapolis, Minnesota, United States

A

Anja Metzger

UNIVERSITY OF MINNESOTA, Lake Elmo, Minnesota, United States

M

Mithun Suresh

M Health Fairview, Vadnais Heights, Minnesota, United States

N

Nicolas Segond

CHU Grenoble Alpes, Grenoble, France

K

Keith Lurie

UNIV OF MINNESOTA HLTH CTR, Minneapolis, Minnesota, United States