Abstract Sun105: Effects of a Flow Modulation Valve on Manual Ventilation Performance and Hemodynamics During Hemorrhagic Shock Resuscitation

D David Salcido (UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States) J Jorge Gumucio (UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States) R Rameen Forghani (UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States) N Nina Lane (UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States) A Arthur Slutsky (University of Toronto, Toronto, Ontario, Canada) J James Menegazzi (UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States)

Abstract

Background: Hemorrhagic shock, precipitated by rapid blood loss, is highly lethal. Successful treatment requires rapid stabilization to prevent mortality. Ventilatory support may be required when accompanied by respiratory failure, and in austere prehospital settings is most likely to occur via manual bagging, which carries risks of barotrauma and hemodynamic compromise. Airway flow limiting devices can facilitate correct manual ventilation, but their utility in the hemorrhagic shock resuscitation setting is not well established. Objective: Evaluate the use of an airway flow limiting device on manual ventilation performance and hemodynamics in a preclinical model of hemorrhagic shock resuscitation. Methods: We sedated, anesthetized and intubated 20 mixed-breed Yorkshire swine, mean(SD) weight 53.1(4) kg. Animals were mechanically ventilated at 8mL/kg while undergoing instrumentation (pressure transducer in descending aorta via femoral cutdown for assessing mean arterial pressure (MAP) and systolic blood pressure (SBP)). Airway flow, pressure (P AW ) and tidal volume (V T ) were monitored continuously. We bled animals in 60cc draws until MAP <40mmHg, and then commenced manual bagging, with animals randomized to standard ventilation (“SHAM”) or flow modulated ventilation (“FM”; Sotair, SafeBVM, Inc). Respiratory rate was guided by a metronome, dynamically adjusted to maintain eucapnia. After 30 min, all withdrawn blood was returned and bagging continued for another 30 min. Performance and hemodynamic parameters were compared between groups and across shock&resuscitation phases (t-tests; ANOVA). a = 0.05 was the threshold for statistical significance. Results: Fourteen pigs survived initial hemorrhage until randomization (1 animal arrested during resuscitation) and initiation of bagging (FM, n = 7; SHAM, n = 7). Airway performance parameters differed between FM and SHAM (p<0.001). MAP and SBP did not differ between FM and SHAM groups but differed between phases (p<0.001). Conclusions: Bagged ventilations with a flow modulation device resulted in more favorable ventilation performance, but no differences in hemodynamics during hemorrhagic shock/resuscitation.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (6)

D

David Salcido

UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States

J

Jorge Gumucio

UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States

R

Rameen Forghani

UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States

N

Nina Lane

UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States

A

Arthur Slutsky

University of Toronto, Toronto, Ontario, Canada

J

James Menegazzi

UNIVERSITY OF PITTSBURGH, Pittsburgh, Pennsylvania, United States