Abstract 4371051: Comparative Effectiveness and Safety of Left Atrial Appendage Occlusion Devices: A Comprehensive Systematic Review and Meta-Analysis

N Nirmit Patel (NYMC - St. Mary's&St Clare's Health, Denville, New Jersey, United States) K Kaushal Patel (NYMC St Mary's General and St Clare, Parsippany, New Jersey, United States) S Sunil Bogati (NYMC - St. Mary's and St. Clare's, Denville, New Jersey, United States) S Shalin Rawal (NYMC - St. Mary's and St. Clare's, Denville, New Jersey, United States) S Siddharth Agrawal (New York medical college landmark, Woonsocket , Rhode Island, United States) G Gaurav Patel (NYMC St Micheal's Medical Center, Newark, New Jersey, United States) A Atul Prakash (St Marys General Hospital, Passaic, Cedar Grove, New Jersey, United States)

Abstract

Background: Percutaneous left atrial appendage occlusion (LAAO) is increasingly utilized for stroke prevention in non-valvular atrial fibrillation (NVAF) patients with contraindications to long-term anticoagulation. With growing global use of WATCHMAN, Amplatzer Amulet, and LAmbre devices, a comprehensive comparison integrating randomized controlled trials (RCTs) and real-world evidence is warranted. Methods: We conducted a systematic review and meta-analysis of RCTs, registries, and observational studies from PubMed, Scopus, Embase, and Cochrane (through June 2025), including studies reporting outcomes for WATCHMAN (2.5 and FLX), Amplatzer Amulet, and LAmbre. Primary endpoints included ischemic stroke, systemic embolism, all-cause mortality, major bleeding, device-related thrombus (DRT), peri-device leak (PDL), and procedural complications. Subgroup analyses assessed device type, CHADS 2 -VASc score, imaging modality (ICE vs TEE), and LAA anatomy. Random-effects models pooled trial and real-world data. Results: We analyzed 27 studies (12 RCTs, 15 observational; 65,308 patients). Procedural success exceeded 97% across devices. Annual ischemic stroke rates were 1.5% (WATCHMAN), 1.4% (Amulet), and 1.2% (LAmbre) (p=NS); all-cause mortality was 3.6%, 3.5%, and 3.3%, respectively. Major bleeding rates were 3.0% (WATCHMAN), 2.7% (Amulet), and 2.8% (LAmbre), with WATCHMAN FLX significantly reducing bleeding vs WATCHMAN 2.5 (OR 0.68, 95% CI 0.49–0.92). DRT occurred in 1.9% (WATCHMAN), 1.3% (Amulet), and 0.9% (LAmbre). Significant PDL (>5 mm) was highest with WATCHMAN (3.2%), lower with Amulet (1.1%) and LAmbre (0.7%). Device embolization occurred in 0.5% (Amulet), 0.2% (WATCHMAN), and 0% (LAmbre), while pericardial effusion rates were 3.1%, 2.8%, and 1.5%, respectively. ICE guidance improved procedural success (OR 1.11, 95% CI 1.03–1.21) but increased pericardial effusion risk (OR 1.22, 95% CI 1.05–1.42) vs TEE. Efficacy was consistent across CHADS 2 -VASc scores (mean 3.8 ± 1.3). LAmbre demonstrated superior adaptability in complex anatomies, including large ostia (≥31 mm), bilobed morphologies, and persistent thrombus. Conclusion: LAAO devices are safe and effective for stroke prevention in NVAF, with device-specific differences. Real-world data highlight LAmbre’s suitability for complex anatomies and Amulet’s lower leak rates. Optimal outcomes depend on individualized device selection based on anatomy, imaging, and bleeding risk.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (7)

N

Nirmit Patel

NYMC - St. Mary's&St Clare's Health, Denville, New Jersey, United States

K

Kaushal Patel

NYMC St Mary's General and St Clare, Parsippany, New Jersey, United States

S

Sunil Bogati

NYMC - St. Mary's and St. Clare's, Denville, New Jersey, United States

S

Shalin Rawal

NYMC - St. Mary's and St. Clare's, Denville, New Jersey, United States

S

Siddharth Agrawal

New York medical college landmark, Woonsocket , Rhode Island, United States

G

Gaurav Patel

NYMC St Micheal's Medical Center, Newark, New Jersey, United States

A

Atul Prakash

St Marys General Hospital, Passaic, Cedar Grove, New Jersey, United States