Abstract 4370550: Device-Related Thrombosis on Watchman Implant: A Case Study Highlighting the Importance of Hypercoagulable Workup

V Vikas Yellapu (St.Luke's University Health Network, Bethlehem, Pennsylvania, United States) E Eluwana Amaratunga (ST. LUKE'S CARDIOLOGY, Bethlehem, Pennsylvania, United States) S Spandan Desai (ST. LUKE'S CARDIOLOGY, Bethlehem, Pennsylvania, United States) M Mihir Ankola (St Luke's University Health Network, Easton , Pennsylvania, United States) J Jovan Plamenac (ST. LUKE'S CARDIOLOGY, Bethlehem, Pennsylvania, United States) P Purujit Thacker (ST. LUKE'S CARDIOLOGY, Bethlehem, Pennsylvania, United States)

Abstract

68-year-old female with history of non-valvular atrial fibrillation who was unable to tolerate anti-coagulation due to multiple episodes of GI bleeds. She underwent left atrial appendage occlusion with a WATCHMAN (Boston Scientific). A 45 day post watchman implant did not reveal a leak and showed appropriate occlusion. Three months post-implantation, routine transesophageal echocardiography (TEE) revealed a small thrombus on the device. Patient was placed back on Rivaroxaban for 3 months. Repeat TEE showed resolution of the thrombus, and was taken of AC. One month after her last TEE (7 months after implantation); The patient presented to the emergency department with acute onset of right-sided hemiparesis and aphasia. Initial work up ECG showed rate controlled atrial fibrillation, with no change from prior ECGs. No significant elevations in cardiac biomarkers. Computed tomography angiography showed an acute left middle cerebral artery occlusion, confirmed by MRI. Emergency thrombectomy was performed. Urgent TEE was obtained; showed a massive frond like thrombus that encompassed the left atrium and originated on the Watchman device. The thrombus originated at the site of the occluder device. Given the recurrence of thrombus, patient underwent a hypercoagulable workup which was consistent with Anti-phospholipid antibody syndrome(APS) (Lupus anticoagulant elevated). Patient was recommended to switch to warfarin as treatment for APS and ASA. Repeat TEE 6 months later show improvement in the size of the thrombus (1.33 cm by 0.76 cm). Thankfully, there were no more episodes for GI bleeds or strokes during this period of time. Device-related thrombosis risk: The incidence of device-related thrombosis following Watchman implantation is reported to be approximately 3-4%. While most cases respond to anticoagulation, some patients may develop recurrent thrombosis. It is important to understand the factors that contribute to thrombus formation. Importance of hypercoagulable workup: The patient's underlying antiphospholipid syndrome was not identified prior to device implantation. This case underscores the necessity of conducting a thorough hypercoagulable workup in patients considered for left atrial appendage occlusion devices. Regular follow-up with imaging studies is crucial for early detection and management of device-related complications. In this case, routine TEE at three months post-implantation allowed for timely detection and treatment of the initial thrombus.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (6)

V

Vikas Yellapu

St.Luke's University Health Network, Bethlehem, Pennsylvania, United States

E

Eluwana Amaratunga

ST. LUKE'S CARDIOLOGY, Bethlehem, Pennsylvania, United States

S

Spandan Desai

ST. LUKE'S CARDIOLOGY, Bethlehem, Pennsylvania, United States

M

Mihir Ankola

St Luke's University Health Network, Easton , Pennsylvania, United States

J

Jovan Plamenac

ST. LUKE'S CARDIOLOGY, Bethlehem, Pennsylvania, United States

P

Purujit Thacker

ST. LUKE'S CARDIOLOGY, Bethlehem, Pennsylvania, United States