Abstract 4369860: Deep Learning Segmentation for Automated Measurement of Infarct Size in Preclinical Myocardial Infarction Models

R Rashid Alavi J Jiajun Li J Jason Lin W Wangde Dai N Niema Pahlevan (University of Southern California, Los Angeles, California, United States) M Morteza Gharib (Department of Medical Engineering, California Institute of Technology) R Robert Kloner (Huntington Medical Research Inst., Pasadena, California, United States)

Abstract

Introduction: Myocardial infarct size (IS) is the most robust endpoint for evaluating cardioprotective strategies in preclinical ischemia/reperfusion studies. The gold standard for IS quantification in preclinical studies (triphenyl tetrazolium chloride (TTC) staining) is traditionally performed manually and is prone to inter-operator variability. Here, we propose a deep learning segmentation pipeline to automate IS quantification in TTC-stained rat heart sections. Methods: We used n=165 Sprague-Dawley rats (150–300 g, 1–2 months, 69% female). Myocardial infarction (MI) was induced using a standard occlusion/reperfusion model by occluding the proximal left coronary artery for 30 minutes, followed by 3 hours of reperfusion. After euthanasia, the left ventricle (LV) was excised, transversely sliced, and incubated in 1% TTC at 37 °C for 15 minutes to distinguish necrotic myocardium (pale white) from viable tissues (brick red, Fig. 1). Manual IS was quantified by contouring infarcted and total LV areas in each slice using ImageJ (NIH, USA). To automate the IS measurement from TTC-stained heart slices, we implemented a deep learning segmentation pipeline based on the mask region-based convolutional neural network (Mask R-CNN) architecture. Ground truth masks for infarcted regions and LV area were created using VGG Image Annotator. Images from n=140 rats were used for training, as well as an additional 1,400 images generated by data augmentation. All training and preprocessing pipelines were conducted in Python. Dice similarity coefficient (Dice score) was used to evaluate the model performance. The best-performing Mask R-CNN model was blindly tested on 25 additional MI rats. Results: Infarct sizes calculated from Mask R-CNN-generated segmentations showed strong agreement with the ones from expert-annotated manual segmentations from TTC-stained LV slices (R = 0.97, p < 0.0001) when tested on heart slices from 25 additional MI rats, supporting the model’s accuracy and validity. Conclusions: Our results demonstrate that deep learning segmentation accurately and automatically quantifies infarct size from TTC-stained images without operator input. This automated approach is rapid, reproducible, and unbiased, significantly reducing inter-operator variability and manual workload in preclinical studies. By streamlining infarct size assessment in preclinical cardio-protection studies, it has the potential to improve consistency and translational value in cardiac research.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (7)

R

Rashid Alavi

J

Jiajun Li

J

Jason Lin

W

Wangde Dai

N

Niema Pahlevan

University of Southern California, Los Angeles, California, United States

M

Morteza Gharib

Department of Medical Engineering, California Institute of Technology

R

Robert Kloner

Huntington Medical Research Inst., Pasadena, California, United States