Abstract 4366162: Electrical Stimulation Enhances Contractile Performance of Tissue-Engineered Pulsatile Conduits with hiPSC-Derived Cardiomyocytes

H Hangqi Luo (Yale University, New Haven, Connecticut, United States) C Christopher Anderson (University of Tennessee, Knoxville, Tennessee, United States) X Xin Li Y Yinsheng Lu M Marie Hoareau (Yale University, New Haven, Connecticut, United States) Q Qinzhe Xing (Yale University, New Haven, Connecticut, United States) S Saba Fooladi Y Yufeng Liu (Key Laboratory of Artificial Structures and Quantum Control (Ministry of Education), School of Physics and Astronomy) Z Zhen Xu J Jinkyu Park J Jordan Thomas P Peter Gruber (Yale University School of Medicine, New Haven, Connecticut, United States) R Robert Elder (Yale School of Medicine, New Haven, Connecticut, United States) M Michael Mak M Muhammad Riaz (Yale Cardiovascular Research Center, Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine) S Stuart Campbell (Yale University, New Haven, Connecticut, United States) Y Yibing Qyang (Yale Cardiovascular Research Center, Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine)

Abstract

Single ventricle congenital heart defects (SVCHDs) are characterized by the presence of only one functional ventricular chamber. The Fontan procedure, a common palliative intervention, reroutes venous blood from the inferior vena cava directly to the pulmonary arteries using a static conduit. However, the absence of contractility results in passive flow, causing venous congestion and poor pulmonary perfusion. We hypothesize that introducing a conduit with pulsatile function could actively pump venous blood into the lungs and reduce stasis. To test this, we first generated engineered heart tissues (EHTs) by seeding human iPSC-derived cardiomyocytes (hiPSC-CMs) onto decellularized porcine heart matrix (Fig. 1A). These cells expressed cardiac troponin T (cTnT), with initially sparse Connexin 43 (Fig. 1B). Subsequently, two layers of EHTs were wrapped around decellularized human umbilical arteries to fabricate the tissue-engineered pulsatile conduit (TEPC), which were then cultured in a bioreactor under continuous electrical stimulation (Fig. 1C-E). Luminal pressure generated by the TEPCs was measured under spontaneous beating and at pacing frequencies of 1, 1.33, 1.66, and 2 Hz. Under spontaneous conditions, the TEPCs generated a luminal pressure of 0.96 mmHg. With electrical pacing, the luminal pressure increased progressively, reaching 1.07 ± 0.07 mmHg at 1 Hz, 1.45 ± 0.32 mmHg at 1.33 Hz, and 1.61 ± 0.25 mmHg at 1.66 Hz. At 2 Hz, the luminal pressure peaked at 1.87 ± 0.33 mmHg, indicating enhanced contractile performance with electrical stimulation (Fig. 1F). In addition, the molecular characteristics of the TEPCs with/without electrical pacing were evaluated. Immunofluorescence analysis demonstrated that paced TEPCs exhibited higher expression levels of cTnT, compared to non-paced controls. Moreover, the expression of Connexin 43 was notably upregulated in electrically stimulated TEPCs, with Connexin 43 predominantly localized at intercellular junctions, indicating enhanced gap junction formation and cellular connectivity. In contrast, TEPCs cultured without electrical pacing showed reduced Connexin 43 expression (Fig. 2). These results demonstrate that electrical stimulation significantly enhances the contractile performance of TEPCs. Our work presents a proof-of-concept strategy for developing a pulsatile conduit as a potential curative therapy for SVCHDs, establishing a critical foundation for future clinical translation.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (17)

H

Hangqi Luo

Yale University, New Haven, Connecticut, United States

C

Christopher Anderson

University of Tennessee, Knoxville, Tennessee, United States

X

Xin Li

Y

Yinsheng Lu

M

Marie Hoareau

Yale University, New Haven, Connecticut, United States

Q

Qinzhe Xing

Yale University, New Haven, Connecticut, United States

S

Saba Fooladi

Y

Yufeng Liu

Key Laboratory of Artificial Structures and Quantum Control (Ministry of Education), School of Physics and Astronomy

Z

Zhen Xu

J

Jinkyu Park

J

Jordan Thomas

P

Peter Gruber

Yale University School of Medicine, New Haven, Connecticut, United States

R

Robert Elder

Yale School of Medicine, New Haven, Connecticut, United States

M

Michael Mak

M

Muhammad Riaz

Yale Cardiovascular Research Center, Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine

S

Stuart Campbell

Yale University, New Haven, Connecticut, United States

Y

Yibing Qyang

Yale Cardiovascular Research Center, Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine