Abstract 4364767: Two Mechanisms, One Valve: A Structural and Hemodynamic Comparison of Rheumatic and MAC-Induced Mitral Stenosis

M Mohammad Hashemi P Peter Abdelmaseeh (EINSTEIN CARDIOLOGY ASSOC, Philadelphia, Pennsylvania, United States) A Atif Nehvi (EINSTEIN CARDIOLOGY ASSOC, Philadelphia, Pennsylvania, United States) G Gregg Pressman (Jefferson Einstein Hospital, Philadelphia, Pennsylvania, United States) A Arash Kheradvar (UNIVERSITY OF CALIFORNIA IRVINE, Irvine, California, United States)

Abstract

Background: Mitral annular calcification (MAC) and rheumatic heart disease represent two distinct mechanisms leading to mitral stenosis (MS). MAC is a common degenerative process associated with increased cardiovascular risk, often resulting in anatomically and hemodynamically unique forms of MS. In contrast, rheumatic mitral stenosis (RMS) arises from inflammatory scarring and commissural fusion. These differing pathophysiologies produce distinct structural and flow characteristics that challenge conventional diagnostic and therapeutic strategies. Understanding these contrasts is essential for accurate assessment and tailored management of MS. Research Questions/Hypothesis: This study aimed to 1) compare structural and flow characteristics, including kinetic energy losses, among MAC-related MS, rheumatic MS (RMS), and normal mitral valves (NMV), and 2) assess the relevance of conventional diagnostic metrics in MAC. We hypothesized that MAC-related MS has distinct structural and hemodynamic features compared to RMS and NMV. Methods: We analyzed 3D transesophageal echocardiographic data from 70 patients (22 NMV, 26 RMS, 22 MAC). Linear, area, and volumetric measurements characterized each valve type. Representative valves were 3D-printed in silicone for in vitro testing in a heart flow simulator. Transmitral flow was visualized via Particle Image Velocimetry (PIV), and flow energetics were quantified. Coefficients of contraction (CoC) were calculated from geometric and effective orifice areas. Results: Compared to RMS, MAC MS had smaller antero-posterior annulus dimensions, reduced valve volume, and lower CoC. MAC showed the highest transmitral velocities and energy loss in vitro. Neither MAC nor RMS models formed transmitral vortex rings, unlike the normal model. Despite a larger geometric orifice, MAC caused a greater pressure drop than RMS, likely due to disrupted flow and lower CoC. These changes in geometry and flow may affect left ventricular function. Conclusions: The lack of transmitral vortex rings in MAC and RMS, combined with higher velocities and energy loss in MAC, reflects altered flow dynamics versus normal valves. These results highlight the need for disease-specific diagnostics and multimodal imaging to improve clinical decisions and guide therapies. Limitations include 2D velocity measurements and reliance on three valve models. Future work should explore more valve types and conditions.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (5)

M

Mohammad Hashemi

P

Peter Abdelmaseeh

EINSTEIN CARDIOLOGY ASSOC, Philadelphia, Pennsylvania, United States

A

Atif Nehvi

EINSTEIN CARDIOLOGY ASSOC, Philadelphia, Pennsylvania, United States

G

Gregg Pressman

Jefferson Einstein Hospital, Philadelphia, Pennsylvania, United States

A

Arash Kheradvar

UNIVERSITY OF CALIFORNIA IRVINE, Irvine, California, United States