Abstract 4364241: Echocardiographic Differences Between Acute Cellular and Antibody-Mediated Rejection in Heart Transplant Recipients

N Nathan Velarde D David Ouyang J Jon Kobashigawa (CEDARS-SINAI HEART INSTITUTE, Los Angeles, California, United States) A Andriana Nikolova (CEDARS SINAI MEDICAL CENTER, West Hollywood, California, United States)

Abstract

Background: Echocardiography is routinely used to evaluate heart transplant rejection, but phenotypic differences between acute cellular rejection (ACR) and antibody-mediated rejection (AMR) are poorly characterized. We aimed to assess echocardiographic features associated with each rejection type and identify differential patterns of structural and functional change. Methods: We included 144 heart transplant recipients (ACR: n = 74, AMR: n = 70) with an echocardiogram at the time of rejection between 2009–2021. ACR was defined as ISHLT grade ≥2R and AMR as pAMR ≥1. Echocardiographic parameters included LVEF, wall thickness, internal diameters, and diastolic indices when available. Baseline echocardiograms performed ≥30 days (or ≥7 days in cases of early rejection) prior to rejection were available in 112 cases, and changes from baseline were calculated. Within-group changes were assessed using the Wilcoxon signed-rank test. Between-group differences at the time of rejection and in change from baseline were analyzed using the Mann-Whitney U test. Results: At the time of rejection, patients with AMR had a significantly smaller left ventricular systolic dimension compared to ACR (2.73 ± 0.51 cm vs. 3.01 ± 0.74 cm, p = 0.03). Within the ACR group, ejection fraction declined from 61.8 ± 8.6% at baseline to 55.0 ± 15.3% at rejection (p = 0.0007), and lateral e′ velocity decreased from 11.7 ± 3.3 cm/s to 10.0 ± 3.5 cm/s (p = 0.005). In the AMR group, the E/e′ ratio declined significantly from 10.8 ± 3.8 to 10.1 ± 3.4 (p = 0.03). Delta comparisons showed that lateral e′ increased in AMR (+1.46 cm/s) but decreased in ACR (–1.70 cm/s), with a significant between-group difference (p = 0.005). E/e′ ratio decreased in AMR (–2.81) and slightly increased in ACR (+0.32), also differing significantly between groups (p = 0.04). Additionally, LVIDd showed a small increase in ACR (+0.10 cm) and a decrease in AMR (–0.09 cm; p = 0.03). Conclusion: Echocardiographic changes in heart transplant rejection differ by rejection type. ACR was associated with declines in systolic and diastolic function, while AMR showed preserved systolic function and opposing patterns in tissue Doppler indices. Dynamic changes in diastolic velocities may aid in distinguishing ACR from AMR, potentially improving diagnostic phenotyping beyond static measurements alone.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (4)

N

Nathan Velarde

D

David Ouyang

J

Jon Kobashigawa

CEDARS-SINAI HEART INSTITUTE, Los Angeles, California, United States

A

Andriana Nikolova

CEDARS SINAI MEDICAL CENTER, West Hollywood, California, United States