Abstract 4364027: ANDES-CHD-AI study: A New algorithm DEtectS critical Congenital Heart Disease using Artificial Intelligence at different altitudes
Abstract
Background: Critical congenital heart disease (CCHD) screening algorithms based on pulse oximetry have up to 27% false positive rate at high altitudes (>2500 m) despite altitude-specific cutoff changes. We examined the added value of an adult-based AI model applied to phonocardiography (AI-PCG) in the digital stethoscope EKO Core 500 in these settings. Research Question: What is the diagnostic performance of AI-PCG model compared to pulse oximetry in detecting neonatal CCHD across different altitudes in Latin America? Methods: This observational, prospective, case-control study included newborns born at different altitudes from 0 to 4380 meters in Peru, Mexico, Colombia and Bolivia. All underwent preductal and postductal oximetry at least 18 hours after birth, electrocardiography and PCG with the digital stethoscope. All CCHD cases were confirmed by echocardiography. Non-CCHD cases were defined by echocardiography or clinically if they were alive for 1 month and had 1) negative pulse oximetry, 2) no hospitalization due to cardiac or pulmonary causes and 3) no cyanosis or pneumonia. Those with abnormal pulse oximetry, genetic syndromes or murmur detection underwent echocardiography. Diagnostic performance metrics [area under the receiving operating characteristic curve (AUROC), sensitivity, specificity and false positive rate] were evaluated per modality. Results: A total of 1152 newborns were enrolled, 725 at <2500 m [13 (1.8%) with CCHD] and 427 at >2500 m [6 (1.4%) with CCHD]. Out of 19 CCHD cases, 17 had positive pulse oximetry and 9 had a positive AI-PCG model. One newborn with severe coarctation of the aorta and atrial septal defect had negative pulse oximetry and AI-PCG model. Pulse oximetry showed superior AUROC (0.932 vs 0.664), sensitivity (89.5% vs 47.4%), specificity (97% vs 85.5%) and lower false positive rate (3% vs 14.5%) compared to the AI-PCG model across altitudes. Diagnostic accuracy varied with altitude (Figure): at <2500 m, pulse oximetry showed higher AUROC (0.999 vs 0.612) and lower false positive rate (0.1% vs 16%) than AI-PCG model, but at >2500 m, pulse oximetry had similar AUROC (0.794 vs 0.774) and lower false positive rate (7.8% vs 11.9%) than the AI-PCG model. Conclusion: Pulse oximetry has superior diagnostic performance than an adult-based AI-PCG model when screening for neonatal CCHD at <2500 m, but similar performance is found >2500 m.
Article Details
Authors (25)
Katia Bravo-Jaimes
Mayo clinic, Jacksonville, Florida, United States
Milagros Nombera Aznaran
UPCH, Lima, Peru
Carmen Davila
Instituto Nacional Materno Perinatal, Lima, Peru
Priscila Carol Tolentino Gabancho
Hospital Regional Docente Madre Nino El Carmen, Huancayo, Peru
Paulina Ordaz
Hospital San Juan del Rio, Queretaro, Mexico
Leslie Martinez
Clinica Universitaria Colombia, Bogota, Colombia
Jorge Galdos
Hospital Regional de Cusco, Cusco, Peru
WILLIAM WALT ROSALES CLAUDIO
Hospital II Pasco, Cerro de Pasco, Peru
Edgar Chavez
Hospital de la Mujer, La Paz, Bolivia, Plurinational State of
Majhifl Mallma
Hospital Regional Honorio Delgado Espinoza, Arequipa, Peru
Grishma Sharma
Mayo Clinic, Jacksonville, Florida, United States
Norma Gamarra-Valverde
UPCH, Lima, Peru
Luis Velarde Zegarra
UNMSM, Lima, Peru
Karem Beatriz Blas Ortiz
UNMSM, Lima, Peru
Daniel Odiseo Cordova Paucarchuco
Hospital Regional Docente Madre Nino El Carmen, Huancayo, Peru
Beatriz Regina Astete Valdez
Hospital II Pasco, Cerro de Pasco, Peru
Joaquin Aguirre Jimenez
Hospital San Juan del Rio, Queretaro, Mexico
Nicol Alexandra Cutipa Apaza
Hospital Regional Honorio Delgado Espinoza, Arequipa, Peru
Luisa Fernanda Jaramillo Ospina
Clinica Universitaria Colombia, Bogota, Colombia
Jenny Triveno Huamannahui
Hospital Regional de Cusco, Cusco, Peru
Diana Nathaly Avila Arias
Clinica Universitaria Colombia, Bogota, Colombia
Mabel Laura Cabrera
Hospital de la Mujer, La Paz, Bolivia, Plurinational State of
Alessandra Vargas Montano
Hospital de la Mujer, La Paz, Bolivia, Plurinational State of
Christopher McLeod
Mayo clinic, Jacksonville, Florida, United States
Rickey Carter
Mayo clinic, Jacksonville, Florida, United States