Abstract 4362887: Effect of Medical-Grade Mask Use on Exercise Physiology in Healthy Adults: A Randomized Crossover Study

J Ju-Hee Lee G Goo Joo Lee (Seoul National University Hospital, Seoul, Korea (the Republic of)) M Mingyu Kang S Sang yong Eom (Chungbuk National University College of Medicine, Cheongju, Korea (the Republic of))

Abstract

Background: Respirator masks are widely used in East Asia for air pollution and, since COVID-19, in public health. However, their physiological impact during exercise remains poorly understood. We evaluates cardiopulmonary responses to exercise under three conditions: no mask, KF80 (Korean Filter; ≥80% filtration of 0.6 μm particles), and KF94 (≥94% filtration of 0.4 μm particles; functionally equivalent to N95). Methods: Forty healthy adults (mean age 33.3 ± 7.2 years, 50% female) underwent a randomized crossover trial, performing cardiopulmonary exercise testing (CPET) using a modified Bruce protocol under no mask, KF80, and KF94. Each session was separated by ≥48 hours. Gas exchange and physiological variables were measured in real time. Outcomes included peak oxygen uptake (VO 2 max), metabolic equivalents (METs), heart rate (HR), tidal volume (VT), minute ventilation (VE), respiratory rate (RR), respiratory exchange ratio (RER), oxygen saturation (SpO 2 ), and systolic blood pressure (SBP). Repeated-measures ANOVA with Bonferroni correction was applied. Results: VO 2 max and METs both declined with greater filtration: VO 2 max was 35.6 ± 8.7 ml/kg/min (No Mask), 31.0 ± 6.5 (KF80), and 29.9 ± 8.0 (KF94; p < 0.001); METs were 7.8 ± 1.3, 6.8 ± 1.2, and 6.2 ± 1.4, respectively ( p < 0.001). Maximal HR decreased from 181.9 ± 15.7 bpm (No Mask) to 176.6 ± 15.9 (KF80) and 171.0 ± 15.3 (KF94; p < 0.001). At 3-min post-exercise, HR remained lower under KF94 (104.2 ± 20.8 bpm) than No Mask (112.6 ± 21.5; p = 0.026), suggesting delayed autonomic recovery. SpO 2 at VO 2 max declined under KF94 (91.8 ± 4.3%) relative to No Mask (94.1 ± 3.0%) and KF80 (93.0 ± 4.2%; p = 0.012); 9 of 40 subjects experienced SpO 2 < 80%. All ventilatory measures declined with increased mask filtration: VE was 66.4 ± 24.3 (No Mask), 43.0 ± 16.8 (KF80), 35.2 ± 15.6 L/min (KF94; p < 0.001); VT was 1.9 ± 0.6, 1.4 ± 0.6, and 1.2 ± 0.4 L ( p < 0.001); and RR was 35.6 ± 8.7, 31.0 ± 6.5, and 29.9 ± 8.0 bpm ( p < 0.01). RER remained unchanged across conditions ( p = 0.24), suggesting consistent metabolic substrate utilization and comparable anaerobic thresholds. Conclusion: KF94 respirators reduce aerobic capacity, maximal HR, and ventilatory efficiency in healthy adults without causing hemodynamic instability. Reduced VO 2 max, blunted HR response, and episodes of desaturation underscore performance trade-offs. These findings support cautious mask use during exertion within evolving post-pandemic health policy.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (4)

J

Ju-Hee Lee

G

Goo Joo Lee

Seoul National University Hospital, Seoul, Korea (the Republic of)

M

Mingyu Kang

S

Sang yong Eom

Chungbuk National University College of Medicine, Cheongju, Korea (the Republic of)