Abstract 4362224: Enhancing Mobility in Mechanical Support: A Retrospective Analysis of Axillary IABP Use
Abstract
Introduction/Background: The axillary approach for intra-aortic balloon pump (IABP) placement offers an alternative to femoral access, with the advantage of preserving mobility during temporary mechanical circulatory support. While femoral insertion is technically easier and widely used, it significantly limits ambulation, potentially worsening outcomes in patients with advanced heart failure (HF) awaiting cardiac replacement therapy. Research Questions/Hypothesis: We evaluated whether axillary IABP maintains mobility while delivering effective hemodynamic support with acceptable safety. We hypothesized that axillary IABP allows ambulation with low complication and device-related morbidity rates. Goals/Aims: We conducted a pooled analysis of four retrospective studies to evaluate outcomes and complications associated with axillary IABP in patients with advanced HF, aiming to better define its role as a bridge to definitive therapies. Methods/Approach: A systematic PubMed search identified four retrospective studies of adult HF patients supported with axillary IABP. Inclusion required reporting of clinical outcomes and/or complications. A random-effects meta-analysis estimated pooled probabilities and 95% confidence intervals (CIs) for key outcomes, accounting for inter-study variability. Significance was set at p<0.05. Results/Data: In 492 patients across the studies, hemodynamic indices - including right atrial pressure, mean pulmonary arterial pressure, pulmonary capillary wedge pressure, and cardiac index - improved following IABP placement. Ambulation was achieved in 92.8% (95% CI: 0.811–0.999). Successful bridging to transplant occurred in 77.7% (95% CI: 0.636–0.918). Mortality (11.4%; 95% CI: 0.001–0.233) and escalation to LVAD or ECMO (6.6%; 95% CI: 0.016–0.117) were low. Vascular complications (5.9%), stroke (2.2%), infection (3.7%), and bleeding (2.8%) were similarly low and not statistically significant. Device failure—including kinking, rupture, migration, or malposition—was the most frequent complication (31.4%; 95% CI: 0.224–0.404). Conclusion(s): Axillary IABP enables ambulation and improves hemodynamics in advanced HF with low complication rates. Device failure is the most common adverse event. Emerging protocols for ambulatory femoral IABP may preserve mobility while potentially reducing device-related issues. Further studies are needed to compare axillary and femoral approaches in terms of safety, durability, and long-term outcomes.
Article Details
Authors (8)
Sara Kwiatkowski
University of Maryland, Baltimore, Maryland, United States
Khalid Alswayed
University of Maryland, Baltimore, Maryland, United States
Olivia Cong
University of Maryland, Baltimore, Maryland, United States
Nageen Sherani
University of Maryland, Baltimore, Maryland, United States
Cullen Soares
University of Maryland, Baltimore, Maryland, United States
Laurence Magder
University of Maryland, Baltimore, Maryland, United States
Gautam Ramani
University of Maryland, Baltimore, Maryland, United States
Haytham Allaham
University of Maryland School of Medicine, Baltimore, Maryland, United States