Abstract 4362160: Validation of Ring-Type Cuffless Blood Pressure (BP) Monitoring Device for Detecting Awake-Asleep BP Variations Compared to Ambulatory BP Monitoring Device

S Seung-Mok Lee (Seoul National University Hospital, Seoul, Korea (the Republic of)) B Bon-Kwon Koo H Hae-Young Lee (Seoul National University Hospital, Seoul, Korea (the Republic of))

Abstract

Introduction: Based on recommendations for validating cuffless BP devices by the European Society of Hypertension (ESH), this is the first validation study assessing the accuracy of CART BP, a ring-type cuffless blood pressure (BP) monitoring device, in detecting awake-asleep BP variations compared to conventional 24-hour ambulatory BP monitoring (ABPM). Unlike traditional cuff-based methods, the ESH validation criteria for cuffless devices emphasize assessing the device's capability to accurately track variations in BP, crucial for their clinical applicability. Hypothesis: We hypothesized that the CART BP device would reliably detect awake-asleep BP variations compared to ABPM, demonstrating a high correlation (correlation coefficient ≥0.7) within an error margin of 5±8 mmHg (mean±standard deviation). Methods: Participants were consecutively selected from initially recruited patients to ensure compliance with ESH recommendations: 30% with systolic BP (SBP) ≥130 mmHg and diastolic BP (DBP) ≥80 mmHg, and 30% with SBP <120 mmHg and DBP <70 mmHg, with the remaining 40% included sequentially based on recruitment order. Calibration of the CART BP device was performed at least 24 hours prior to monitoring. Participants simultaneously wore both the CART BP and ABPM devices on the non-dominant arm for 24 hours. Mean SBP/DBP values were calculated from ABPM and CART BP readings. The SBP/DBP changes between awake and asleep periods were compared. Results: Of the 84 initially recruited participants, 35 were included in the final analysis: 30% (N=11) had SBP/DBP ≥130/80 mmHg, 30% (N=11) had SBP/DBP <120/70 mmHg, and the remaining 40% (N=13) were enrolled sequentially. The awake-asleep SBP/DBP changes were 15.61±8.74 / 11.35±6.22 mmHg with ABPM, and 14.15±9.18 / 11.61±8.85 mmHg with CART BP. Correlation coefficients were 0.73 for SBP and 0.74 for DBP (p<0.001 for both). Mean differences in awake-asleep BP changes between CART BP and ABPM were -1.46±6.57 mmHg for SBP and 0.26±5.98 mmHg for DBP, with no significant differences (p=0.197 and 0.798, respectively). The prevalence of dippers (74.3% VS 60%, p=0.131) was comparable between both devices. Conclusion: CART BP demonstrated acceptable accuracy in detecting diurnal BP variations, aligning with ESH validation standards for cuffless BP monitoring devices.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (3)

S

Seung-Mok Lee

Seoul National University Hospital, Seoul, Korea (the Republic of)

B

Bon-Kwon Koo

H

Hae-Young Lee

Seoul National University Hospital, Seoul, Korea (the Republic of)