Abstract 4361141: Impact of Aortic Insufficiency Severity on ECPELLA-provided Hemodynamic Support and Left Ventricular Unloading: A Triadic In Vitro–In Vivo–In Silico Analysis

T Takuya Nishikawa (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) T Takashi Unoki (Saiseikai Kumamoto Hospital, Kumamoto, Japan) M Masahiro Otake (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) M Midori Kakuuchi (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) S Shohei Yokota (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) H Hiroki Matsushita (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) K Kei Sato H Hidetaka Morita (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) N NANA HIRAKI (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) K Kenta Ohba (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) Y Yuki Yoshida M Masafumi Fukumitsu (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) K Kazunori Uemura (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) T Toru Kawada (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan) K Keita Saku (National Cerebral and Cardiovascular Center, Suita, Osaka, Japan)

Abstract

Introduction: The combination therapy of venoarterial extracorporeal membrane oxygenation (VA-ECMO) and transaortic valve micro-axial flow pump catheter (Impella), so-called ECPELLA, provides powerful hemodynamic support and left ventricular (LV) unloading for cardiogenic shock (CS). However, aortic insufficiency (AI) caused by Impella placement reduces those benefits of ECPELLA. Research Questions: This study investigated the impact of Impella-induced AI on the effects of hemodynamic support and LV unloading by ECPELLA. We examined the relationship between AI severity and regurgitant flow (AI flow) using mock circulation and confirmed the presence of AI-induced hemodynamic deficit in a goat model of ECPELLA. Furthermore, we evaluated the impact of varying AI severity on hemodynamics and LV pressure-volume (PV) loop in ECPELLA circulation by our developed cardiovascular simulation. Methods: In a closed mock circuit with a centrifugal pump, we evaluated the relationship between the AI severity, which was altered by the position of the Impella at the aortic valve (Fig. 1A), and the effective regurgitant orifice area (EROA) estimated from AI flow and pressure gradient. Five Saanen goats (53±2 kg) were used for animal experiments of ECPELLA (Fig. 1B). VA-ECMO flow was set at 1.0, 1.5, and 2.0 L/min. AI flow was calculated from the difference between pulmonary artery and Impella flows. We developed a cardiovascular simulation that employed four cardiac chambers with resistance-compliance networks incorporating ECPELLA (Fig. 1C). Using four AI severity levels, we calculated the hemodynamics and illustrated PV loops by changing Impella CP settings from P0 to P9 under VA-ECMO support. Results: In mock circulation, AI flow increased according to the pressure gradient in each AI severity. Estimated EROA values were 0.018, 0.056, and 0.75 cm 2 for minimal, mild, and severe AI, respectively (Fig. 2A). In goats with ECPELLA, we observed the presence of AI with EROA of 0.18 cm 2 (Fig. 2B). In the simulation, the higher AI severity markedly attenuated the Impella impact on hemodynamic improvement and the leftward and downward shift in PV loop (Fig. 2C). Conclusion: Inappropriate Impella position can cause severe AI. Severe AI substantially reduces both hemodynamic support and LV unloading effects of ECPELLA. Systematic AI assessment is critical for optimal ECPELLA management in CS patients.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (15)

T

Takuya Nishikawa

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

T

Takashi Unoki

Saiseikai Kumamoto Hospital, Kumamoto, Japan

M

Masahiro Otake

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

M

Midori Kakuuchi

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

S

Shohei Yokota

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

H

Hiroki Matsushita

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

K

Kei Sato

H

Hidetaka Morita

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

N

NANA HIRAKI

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

K

Kenta Ohba

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

Y

Yuki Yoshida

M

Masafumi Fukumitsu

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

K

Kazunori Uemura

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

T

Toru Kawada

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan

K

Keita Saku

National Cerebral and Cardiovascular Center, Suita, Osaka, Japan