Abstract 4353255: Estimating CardioMEMS Pulmonary Artery Diastolic Pressure With a Non-invasive Cardiac Hemodynamic Artificial Intelligence monitoring System (CHAIS)
Abstract
Introduction: The implantable CardioMEMS Heart Failure (HF) system, which monitors pulmonary arterial pressures in an outpatient setting, has been shown to reduce HF hospitalizations and improve functional status in patients with chronic heart failure. However, implantation is invasive and entails risk. Recent evidence suggests that a Cardiac Hemodynamic Artificial Intelligence System (CHAIS) can non-invasively identify when the mean pulmonary capillary wedge pressure (mPCWP) is elevated using ECG Lead-I signals. In this pilot study, we test whether CHAIS, without any retraining, can identify when the pulmonary artery diastolic pressure (PADP) – a correlate of the mPCWP – is elevated using ECG Lead-I signals obtained from a wearable ECG monitor. Hypothesis: CHAIS can determine when CardioMEMS-derived PADP is elevated. Methods: Ten adults (1 female, age 72 ± 11 years) with chronic HF and CardioMEMS implants were enrolled at Boston Medical Center (BMC, n=6, IRB H-44263) and Massachusetts General Hospital (MGH, n=4, IRB 2023P001291). Participants wore a single-lead ECG patch for up to 14 days. ECG data was segmented into 10 second windows, pre-processed, and input to CHAIS, which returned the probability of mPCWP > 18 mmHg. CHAIS probabilities were matched to CardioMEMS-derived PADP, producing N=76 contemporaneous pairs across all 10 patients. Results: CHAIS showed strong discriminatory ability for identifying when CardioMEMS PADP > 18 mmHg, yielding an overall AUC of 0.82 (BMC 0.85; MGH 0.81). After excluding eight ECG signals with poor signal quality (resulting in N=68 ECG-PADP pairs), the overall AUC rose to 0.85 (BMC 0.86; MGH 0.93). Moreover, CHAIS output was positively associated with contemporaneous CardioMEMS PADP (Pearson r=0.36, Spearman ρ=0.45 with N=76 and Pearson r=0.42, ρ=0.51 with N=68; all p < 0.001). P-values were computed via permutation testing using 25,000 resamples. Conclusion: This is the first study to demonstrate that a deep-learning model (CHAIS) can discriminate for elevated PADP using ECG signals obtained from a wearable ECG monitor. This non-invasive low-cost methodology for hemodynamic monitoring could expand HF surveillance, especially for patients who are ineligible to receive an invasive device. Fine-tuning CHAIS on wearable ECG data would improve its ability to non-invasively identify patients at risk for a HF exacerbation.
Article Details
Authors (8)
Zachary Berger
Roey Ringel
Boston University Medical Center, Boston, Massachusetts, United States
Samuel Roytburd
Boston University Medical Center, Boston, Massachusetts, United States
Nir Ayalon
Boston University Medical Center, Boston, Massachusetts, United States
Deepa Gopal
Boston University Medical Center, Boston, Massachusetts, United States
Lana Tsao
Mass General Brigham, Boston, Massachusetts, United States
John Guttag
MA INSTITUTE TECHNOLOGY, Cambridge, Massachusetts, United States
Collin Stultz
MA INSTITUTE TECHNOLOGY, Cambridge, Massachusetts, United States