Abstract 4346878: Comparison of Intra-coronary and Intra-aortic Pressure Recordings for Coronary Wave Intensity Analysis
Abstract
Background: Coronary wave intensity analysis (WIA) provides a mechanistic view of coronary hemodynamics and has been increasingly used to phenotype coronary microvascular disease (CMD). Standard WIA requires simultaneous pressure and flow measurements within the same vessel, but intra-coronary pressure measurement may be limited by hardware availability. In patients with non-obstructive coronary arteries, aortic pressure may serve as a surrogate for intra-coronary pressure to enable broader feasibility of WIA. We aimed to determine whether wave profiles derived from intra-aortic and intra-coronary pressure measurements are comparable when paired with intracoronary Doppler flow in patients with non-obstructive coronary artery disease. Methods: Patients undergoing invasive coronary physiology assessment of the left anterior descending artery were included. Intracoronary flow velocity and intra-coronary pressure were simultaneously recorded using a ComboWire (Philips Volcano) in the proximal LAD. Aortic pressure was concurrently measured via the guide catheter to allow comparison of pressure sources. In the intra-aortic pressure group, pressure and flow data were aligned using the R wave of the ECG trace. WIA was performed using conventional methods to quantify the dominant waves: forward compression wave (FCW), backward compression wave (BCW), and backward expansion wave (BEW). Agreement between wave intensity was assessed using Bland-Altman analysis and Pearson correlation. Results: A total of 14 paired waveforms were analyzed with a total of 42 coronary waves compared. Wave intensities calculated using intra-coronary versus intra-aortic pressure showed excellent agreement across all wave types. Mean bias between methods was −0.07 x 10 3 W×m -2 ×s -1 with limits of agreement from −0.63 to +0.49. The correlation between intra-coronary and intra-aortic wave intensities was strong (r = 0.997, p < 0.001), with minimal dispersion and consistent agreement across the full range of wave intensities ( Figure 1 ). Conclusions: In patients with non-obstructive coronary arteries, wave intensity analysis using guide-catheter aortic pressure yields results nearly identical to those obtained with intra-coronary pressure. These findings support the use of aortic pressure as a reliable surrogate for intra-coronary pressure in WIA for the calculation of microvascular coronary hemodynamics, reducing technical barriers and enabling broader clinical and research utilization.
Article Details
Authors (5)
Justin Carrington
Mayo Clinic, Rochester, Minnesota, United States
Abhiram Prasad
Mayo Clinic, Rochester, Minnesota, United States
Rajiv Gulati
MAYO CLINIC, Rochester, Minnesota, United States
Amir Lerman
Claire Raphael
MAYO CLINIC, Rochester, Minnesota, United States