Abstract 4346878: Comparison of Intra-coronary and Intra-aortic Pressure Recordings for Coronary Wave Intensity Analysis

J Justin Carrington (Mayo Clinic, Rochester, Minnesota, United States) A Abhiram Prasad (Mayo Clinic, Rochester, Minnesota, United States) R Rajiv Gulati (MAYO CLINIC, Rochester, Minnesota, United States) A Amir Lerman C Claire Raphael (MAYO CLINIC, Rochester, Minnesota, United States)

Abstract

Background: Coronary wave intensity analysis (WIA) provides a mechanistic view of coronary hemodynamics and has been increasingly used to phenotype coronary microvascular disease (CMD). Standard WIA requires simultaneous pressure and flow measurements within the same vessel, but intra-coronary pressure measurement may be limited by hardware availability. In patients with non-obstructive coronary arteries, aortic pressure may serve as a surrogate for intra-coronary pressure to enable broader feasibility of WIA. We aimed to determine whether wave profiles derived from intra-aortic and intra-coronary pressure measurements are comparable when paired with intracoronary Doppler flow in patients with non-obstructive coronary artery disease. Methods: Patients undergoing invasive coronary physiology assessment of the left anterior descending artery were included. Intracoronary flow velocity and intra-coronary pressure were simultaneously recorded using a ComboWire (Philips Volcano) in the proximal LAD. Aortic pressure was concurrently measured via the guide catheter to allow comparison of pressure sources. In the intra-aortic pressure group, pressure and flow data were aligned using the R wave of the ECG trace. WIA was performed using conventional methods to quantify the dominant waves: forward compression wave (FCW), backward compression wave (BCW), and backward expansion wave (BEW). Agreement between wave intensity was assessed using Bland-Altman analysis and Pearson correlation. Results: A total of 14 paired waveforms were analyzed with a total of 42 coronary waves compared. Wave intensities calculated using intra-coronary versus intra-aortic pressure showed excellent agreement across all wave types. Mean bias between methods was −0.07 x 10 3 W×m -2 ×s -1 with limits of agreement from −0.63 to +0.49. The correlation between intra-coronary and intra-aortic wave intensities was strong (r = 0.997, p < 0.001), with minimal dispersion and consistent agreement across the full range of wave intensities ( Figure 1 ). Conclusions: In patients with non-obstructive coronary arteries, wave intensity analysis using guide-catheter aortic pressure yields results nearly identical to those obtained with intra-coronary pressure. These findings support the use of aortic pressure as a reliable surrogate for intra-coronary pressure in WIA for the calculation of microvascular coronary hemodynamics, reducing technical barriers and enabling broader clinical and research utilization.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (5)

J

Justin Carrington

Mayo Clinic, Rochester, Minnesota, United States

A

Abhiram Prasad

Mayo Clinic, Rochester, Minnesota, United States

R

Rajiv Gulati

MAYO CLINIC, Rochester, Minnesota, United States

A

Amir Lerman

C

Claire Raphael

MAYO CLINIC, Rochester, Minnesota, United States