Abstract 4344198: Diagnostic efficacy of CT-FFR in coronary artery stenosis of varying severity
Abstract
Background: Although fractional flow reserve (FFR) remains the gold standard for evaluating myocardial ischemia, its invasive nature limits widespread clinical adoption. CT-derived FFR (CT-FFR) offers a noninvasive alternative, yet its diagnostic consistency across different stenosis severity levels remains unclear. This study aims to evaluate the diagnostic accuracy and correlation of CT-FFR compared to invasive FFR, stratified by stenosis severity, to enhance precision in ischemia assessment. Methods: In this prospective study, 138 patients (mean age 62.4 ± 9.7 years; 64.5% male) with suspected or confirmed coronary artery disease (CAD) and stenosis ranging from 30% to 90% in major coronary arteries (≥2.0 mm diameter) underwent coronary CT angiography (CCTA) followed by CT-FFR analysis (Coronary Scope, Shenzhen Yueying Technology Co., Ltd., China). Invasive FFR (St. Jude Medical, Inc., USA) was performed within 15 days post-CCTA as the reference standard. Both CT-FFR and FFR assessments focused on a single target vessel per patient. Ischemia was defined as FFR ≤0.80, with the same threshold applied to CT-FFR. Stenosis severity was categorized into three groups: 30%–49%, 50%–69%, and 70%–90%. Diagnostic performance metrics (sensitivity, specificity) and correlation coefficients (r) were analyzed. Results: CT-FFR demonstrated outstanding diagnostic efficacy, with sensitivity, specificity, and accuracy of 96.2%, 97.7%, and 97.1%, respectively. A robust overall correlation was observed between CT-FFR and invasive FFR (r = 0.832, 95% CI: 0.773–0.877; p < 0.001). Subgroup analysis revealed progressively stronger correlations with increasing stenosis severity: moderate for 30%–49% stenosis (r = 0.700, 95% CI: 0.483–0.836; p < 0.0001), strong for 50%–69% stenosis (r = 0.755, 95% CI: 0.625–0.844; p < 0.0001), and nearly perfect for 70%–90% stenosis (r = 0.914, 95% CI: 0.840–0.955; p < 0.0001). The correlation in the 70%–90% group was significantly superior to the other groups (p < 0.05). Conclusions: CT-FFR exhibits high diagnostic accuracy across a wide spectrum of coronary stenosis (30%–90%), with exceptional performance in severe stenosis (70%–90%). These results underscore the potential of CT-FFR as a frontline noninvasive modality for guiding revascularization strategies, particularly in cases of high-grade stenosis, and advocate for its integration into precision-driven CAD management protocols.
Article Details
Authors (6)
Haoyu Wu
Guang Yang
Yongyong Zhao
Shaanxi Provincial People's Hospital, Xi'an, China
Ju Yan
Shaanxi Provincial People's Hospital, Xi'an, China
Fengchao Wu
Lei Liang