Abstract 4343089: Severe Hypoxic Respiratory Failure After Watchman Device Implantation in a Patient With Bioprosthetic Tricuspid Stenosis and Persistent iASD

S Soroush Shakeri (Maimonides Medical Center, Brooklyn, New York, United States) G Gregory Cunn (Maimonides Medical Center, Brooklyn, New York, United States)

Abstract

Case Description: A 54-year-old male with ESRD on hemodialysis, tricuspid valve endocarditis status post bioprosthetic valve replacement, and atrial fibrillation status post catheter ablation one month prior, underwent elective Watchman device implantation. Following successful device placement, the patient continued to require ventilator support. Intra-procedural TEE revealed a known iatrogenic atrial septal defect (iASD) from prior ablation with a moderate right-to-left shunt and a peak gradient of 16 mmHg. The bioprosthetic tricuspid valve demonstrated severe stenosis. Additional findings included moderate-to-severe tricuspid regurgitation, a severely dilated right atrium, and preserved left ventricular ejection fraction. The patient remained ventilator-dependent and developed septic shock within 24 hours secondary to pneumonia. Despite dialysis and antibiotic therapy, hypoxia persisted. The right-to-left shunt across the iASD, driven by elevated right atrial pressure from severe tricuspid stenosis, was identified as a major contributor. On hospital day 9, the patient underwent transcatheter tricuspid valve replacement. Following the procedure, he improved rapidly, was extubated within 48 hours, and was discharged four days later, off supplemental oxygen and ambulating with support. At 45-day follow-up, he remained asymptomatic. TEE showed a well-functioning tricuspid prosthesis, moderately dilated right atrium, and two small ASDs with predominantly left-to-right flow. Discussion: Transseptal puncture is an essential component of Watchman device implantation. Factors such as the size and stiffness of the delivery sheath, repeated septal instrumentation, or prolonged left atrial dwell time may increase the risk of persistent iASD. Recent studies have shown that up to one-third of patients undergoing left atrial appendage closure may have persistent iASDs at 45-day follow-up, with a smaller subset exhibiting right-to-left shunting often in the context of elevated right-sided pressures. In patients with pre-existing iASDs from prior transseptal procedures, the cumulative impact may result in clinically significant hypoxia following device implantation. In this case, the patient’s hemodynamic instability was further exacerbated by sepsis and volume overload due to ESRD, both of which increased right-sided pressures and worsened the shunt. The definitive intervention involved treating the underlying cause, tricuspid stenosis, rather than closing the iASD.

Article Details

Journal Circulation
Volume / Issue Vol. 152, Issue Suppl_3
Published November 04, 2025
ISSN 0009-7322
Publisher Lippincott Williams & Wilkins

Journal Info

Circulation

Lippincott Williams & Wilkins

ISSN: 0009-7322 Health Sciences

Authors (2)

S

Soroush Shakeri

Maimonides Medical Center, Brooklyn, New York, United States

G

Gregory Cunn

Maimonides Medical Center, Brooklyn, New York, United States