A multi-phase project to develop a patient-reported measure of barriers to antiretroviral therapy adherence for use in HIV care: The 7-Item I-Score
Abstract
Adherence to antiretroviral therapy (ART) is a priority in HIV care. Our goal was to develop and validate a new, short patient-reported outcome measure to screen for barriers to daily oral ART adherence in HIV care in Canada and France. The overarching design was that of a multi-phase, multi-site instrument development project. It involved a previously published qualitative research synthesis (to develop a conceptual framework from which to generate items). Here, we present the results of cognitive interviews (for content validity testing of the preliminary items) and of a longitudinal survey-based study where the revised 7-item instrument (the I-Score) was administered at two timepoints (baseline, 4 weeks), along with five indirect measures of ART adherence, including self-reported HIV viral load and, for a subset of Montreal participants, plasma viral load. The survey data was used to analyze the instrument’s measurement properties, namely structural validity (e.g., with Pearson inter-item correlations); construct validity, including cross-cultural validity, for a variety of sociodemographic groups (with receiver operating curve (ROC) analyses and areas under the curve (AUC); reliability (with the intraclass correlation coefficient (ICC)); and measurement error (with the standard error of measurement (SEM)). Study participants were adults living with HIV on antiretroviral therapy recruited from hospital-based infectious disease centers and community-based organizations in Montreal, Toronto, and Paris. The qualitative synthesis of 41 studies led to a framework composed of 6 barrier domains. One item was generated per domain. The 6-item measure was submitted to cognitive testing with 12 adults living with HIV, leading to several changes, including the division of one item into two, creating a 7-item measure. Overall, 305 adults living with HIV participated in the survey. Inter-item correlations were low to moderate, suggesting no redundant items. Among conclusive results, AUC’s were all above the predefined threshold (≥ 0.70) for self-reported viral load and plasma viral load for the global sample and across all subgroups examined. The ICC, at 0.81, was also above the predefined threshold (≥ 0.70). The SEM was 0.43. Overall, the evidence generated supports the 7-item I-Score measure’s content validity, construct validity/cross-cultural validity, reliability, and acceptable measurement error, in its specified context of use.
Article Details
Authors (6)
Kim Engler
David Lessard
Serge Vicente
Darrell H. S. Tan
Karine Lacombe
Bertrand Lebouché